Data Logger

CL32: 3G Data Logger

- Smart Phone, Tablet, PC. Real Time Monitoring

- 4 Analog Input

- 2 Digital Input (Logic or Counter)

- Built-in 3G Modem (UMTS/HSDPA)

- Centralize data logger (Logger on common Database:

   MySQL, SQL Server)

- Memory 2 Mbyte (Internal)

- Data exportable to MS Excel

- Support External Supply

General Features and Benefits: 

Smart Phone, Tablet, PC. Real Time Monitoring

4 Analog Input

2 Digital Input (Logic or Counter)

Built-in 3G Modem (UMTS/HSDPA)

Centralize data logger (Logger on common Database: MySQL, SQL Server)

Support External Supply

            3G Data Logger CL32 The CL32 is a device designed to record various measurement values. It is capable of measuring both analog and digital (pulse) signals, continuously storing the data in its flash memory with associated timestamps (date and time). The recorded data is transmitted via GPRS over the internet to the servers (MySQL, SQL Server) of a Centralized Data Logging System, allowing for simultaneous data viewing on smartphones, tablets, or PCs.

            Analog Input Selectable measurement signals include 4-20 mA, 0-100 mVDC, 1-5 VDC, 0-5 VDC, and 0-10 VDC, originating from sources such as transmitters or sensor transmitters.

            Digital Input It can accept either Logic or Counter signals. Logic signals indicate an “ON” or “OFF” operational status, while Counter signals track the number of input pulses-such as recording totalized flow or electricity consumption in kWh.

Centralized Data Logging System

Show an overview of the Centralized Data Logging System.

            The figure illustrates a Centralized Data Logging System evolved from a standard server-based database system. Simply put, the CL32 transmits signal data via GPRS over the internet to the system's server; the data stored on the server can then be accessed or managed from anywhere using a computer, PDA, mobile phone, or any other internet-connected device.

            In essence, a Centralized Data Logging System is a network-based, centralized data storage solution that leverages server capabilities and the Internet. Data is aggregated at a central server and distributed via the Internet, facilitating easy management and remote access from any location with connectivity, thereby eliminating the need to physically retrieve data directly from the devices themselves.

Warranty: 
1 year
Specifications

Cellular Interface

Dual Band:

UMTS/HSDPA (900/2100 MHz)

Quad Band:

GSM/GPRS/EDGE (850/900/1800/1900 MHz)

GPRS multi-slot:

Class 12

EDGE multi-slot:

Class 12

WCDMA 3GPP:

Release 5

Output power:

UMTS 850/1900: 0.25W

UMTS 900/2100: 0.25W

GSM 850/GSM 900: 2W

DCS 1800/PCS 1900: 1W

Data Transfer (Max.):

   HSDPA: 3.6 Mbps (DL)

   WCDMA: 384 Kbps (DL), 384 Kbps (UL)

   EDGE Class: 236.8 Kbps (DL), 118 Kbps (UL)

   GPRS: 85.6 Kbps (DL), 42.8 Kbps (UL)

   CSD: GSM data rate 14.4 Kbps

USB Interface

Compliance:

USB 1.1/2.0

Connector:

USB Type B

Speed:

12 Mbps (Full-Speed USB)

Operating System:

Windows 98/SE, ME, NT, 2000, XP, 7, 8, Vista

Analog Input

Number of Channel:

4 channels

Input Type:

Current, Voltage

Input Range:

Current (4 to 20 mA)

Voltage mVDC (0 to 100 mVDC)

Voltage (0 to 5, 1 to 5, 0 to 10 VDC)

ADC Resolution:

16 Bits

Digital Input

Number of Channel:

2 Channels (Logic or Counter, Programmable Input)

Sensor Type:

Wet Contact

ON : 12 to 24 VDC

OFF : 0 to 3 VDC

Isolation:

Opto Isolated

Counter Frequency:

maximum 20 Hz

Minimum Pulse Width:

50 msec

Recording

Storage Internal:

2 Mbyte

Recording Interval:

1 Sec to 1 Hours (Programmable)

Record Mode:

Stop When Full

Data Format:

Can be Exported to MS Excel

Data Capacity:

74,000 Records (6 Channels Input)

Power Requirements

Internal Supply:

Battery 3.6 VDC @ 40 Ah.

External Supply:

12 to 24 VDC

Power Consumption

Standby:

10 mA @ 3.6 VDC

Upload Data:

200 mA @ 3.6 VDC

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W149 x H198 x D102 mm.

Protection:

IP67

Warranty

Warranty Period:

1 year

Ordering
Ordering Information: Specify input range
Example CL32/4-20mA
Packagelist

Package Checklist

1. CL32

2. Antenna

3. USB Cable

Downloads
Group Order
Data Logger: 
19.1

CL28: Ethernet Data Logger

- Smart Phone, Tablet, PC. Real Time

  Monitoring

- 4 Channels Analog Input

- 2 Channels Totalizer

- Ethernet Data Transfer

- Centralize data logger (Logger on

  common SQL Database: MySQL, SQL Server)

- Flash memory 1 MByte

General Features and Benefits: 

Smart Phone, Tablet, PC. Real Time Monitoring

4 Channels Analog Input

2 Channels Totalizer

Ethernet Data Transfer

Centralize data logger (Logger on common Database: MySQL, SQL Server)

Flash memory 1 MByte

            Ethernet Data Logger CL28 This device records both analog and totalized data, transmitting the recorded information via an ADSL modem or router over the internet to the Centralized Data Logging System's servers (MySQL, SQL Server). The data can be viewed simultaneously on smartphones, tablets, or PCs.

            Analog Input Selectable measurement signals include 4-20 mA, 0-100 mVDC, 1-5 VDC, 0-5 VDC, and 0-10 VDC. The CL28 continuously records measurements to its memory, with each entry timestamped with the date and time; real-time monitoring is also supported.

            Totalized Input It counts input pulses and records the count values at user-defined intervals; examples of applications include recording totalized flow values or electricity consumption in kWh.

Connecting to various devices.

Centralized Data Logging System

Show an overview of the Centralized Data Logging System.

            The diagram illustrates a Centralized Data Logging System evolved from a standard server-based database system. Simply put, the CL28 transmits data via an ADSL modem or router over the internet to the system's server; the data stored on the server can then be accessed from anywhere using a computer, PDA, mobile phone, or any other internet-enabled device.

            In essence, a Centralized Data Logging System is a network-based, centralized data storage solution that leverages server capabilities and the Internet. Data is aggregated at a central server and distributed via the Internet, facilitating easy management and remote access from any location with connectivity, thereby eliminating the need to physically retrieve data directly from the devices themselves.

Warranty: 
5 years
Specifications

Ethernet Interface

Number of Port:

1

Connector:

RJ45 (10 Base-T)

Standard:

Accord 10 Base-T/100 Base-T standard

Speed:

10/100 Mbps, Full-duplex, half-duplex

Data Rates:

300 - 115,200 bps

Transmission:

100 m.

USB Interface

Compliance:

USB 1.1/2.0

Connector:

USB Type B

Speed:

12 Mbps (Full-Speed USB)

Class:

CDC

Analog Input

Number of Channel:

4 channels

Input Type:

Current, Voltage

Input Range:

Current (4 to 20mA)

Voltage mVDC (0 to 100 mVDC)

Voltage (0 to 5, 1 to 5, 0 to 10 VDC)

ADC Resolution:

16 Bits

Accuaracy:

± 0.2 % of span

Digital Input

Number of Channel:

2 Channels

Sensor Type:

NPN open collector or dry contact

I/O Mode:

DI or Even Counter

Dry Contact:

ON : Short to GND

OFF : Open

Counter Frequency:

maximum frequency 20 Hz

Minimum Pulse Width:

50 msec

Recording

Storage Internal:

Flash Memory 1 MByte

Recording Interval:

1 Sec to 18 Hours (Programmable)

Record Mode:

Stop When Full

Recording by:

Interval, Schedule, Appointment

Data Format:

Can be Exported to MS Excel

Data Capacity:

37,000 Records

Power Requirements

Power Supply:

12 to 24 VDC

Power Consumption

Standby:

130 mA @ 12 VDC

Start Record:

300 mA @ 12 VDC

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W100 x H123 x D30 mm

Warranty

Warranty Period:

5 year

Ordering
Ordering Information: Specify input range
Example CL28/4-20mA
Packagelist

Package Checklist

1. CL28

2. USB Cable

3. LAN Cable

Downloads
Group Order
Data Logger: 
18

CL24A: Data Logger

- 1 Channel Analog Input (4-20 mA,

  0-10 VDC)

- 2 Channels Totalizer

- Memory 256 KByte

- Data exportable to MS Excel

General Features and Benefits: 

1 Channel Analog Input (4-20 mA, 0-10 VDC)

2 Channels Totalizer

Memory 256 KByte

Data exportable to MS Excel

             Data Logger CL24A This device records small-scale measurement data-specifically analog signals and counter (totalizer) values-continuously within its internal memory, with each entry timestamped. Configurable analog input ranges include 4 - 20 mA, 1 - 5 VDC, 0 - 5 VDC, and 0 - 10 VDC, while the totalizer counts incoming pulses and stores the accumulated totals in memory.

             Data recorded in the CL24A can be retrieved by connecting a computer to the unit via an RS232 port or a modem, using dedicated software to transfer the data. The retrieved data can be displayed on the computer in either numerical or graphical formats. Furthermore, the data is compatible with other Windows-based applications-such as MS Excel-facilitating further calculations and report generation.

Connection to a computer via the Wireless (RC35).

Connection to a computer via the Ethernet (MC330).

Connection to a computer via the Internet (MC331).

Warranty: 
1 year
Specifications

Serial Interface

Serial Standards:

RS232 Connector RJ12

Distance:

RS232 Length 15 m.

Serial Parameter

Baud Rate:

19200

Data Bits:

8

Stop Bits:

1

Parity:

None

Analog Input

Number of Channel:

1 Channel

Input Type:

Current, Voltage

Input Range:

Current (4 to 20 mA)

Voltage (0 to 5, 1 to 5, 0 to 10 VDC Optional)

ADC Resolution:

10 Bits

Accuracy:

± 0.2 % of span

Totalizer Input

Number of Channel:

2 Channels

Sensor Type:

NPN open collector or Dry contact

I/O Mode:

Even Counter

Dry Contact:

ON : Short to GND

OFF : Open

Counter Frequency:

maximum frequency 20 Hz

Minimum Pulse Width:

50 msec

Recording

Storage Internal:

256 Kbytes

Recording Interval:

1 Sec to 18 Hours (Programmable)

Record Mode:

Stop When Full or Roll Over

Recording by:

Magnetic Starter, DI Trig

Data Format:

Can be Exported to MS Excel

Data Capacity:

131,040 Records (3 Channels)

Power Requirements

Power Supply:

Lithium Battery 7.2 VDC@2.4 AH

(2 Year Life Time @ 15 Min. Interval Time)

Power Consumption

Standby:

30 µA @ 7 VDC

Start Record:

500 µA @ 7 VDC

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W95 x H65 x D55 mm.

Protection:

IP65

Warranty

Warranty Period:

5 year

Ordering
Ordering Information: Specify Input Rang
Example CL24A/256Kbytes/4-20mA
Packagelist

Package Checklist

1. CL24A

2. RS-232 Cable

3.Input Cable

Downloads
Group Order
Data Logger: 
14.1

ML28: Even Data Logger

- 4 Channels Digital Input

- ON/OFF Time Stamp

- Memory 128 Kbyte

- Data exportable to MS Excel

General Features and Benefits: 

4 Channels Digital Input

ON/OFF Time Stamp

Memory 128 Kbyte

Data exportable to MS Excel

            Data Logger ML28 This device records the ON/OFF status of digital signals. Data is continuously stored in the internal memory, accompanied by timestamps indicating when the events occurred. It is suitable for installation where monitoring the operational status of machinery-such as pumps, motors, or chillers-is required.

            Data stored in the ML28 can be read by connecting a computer to the ML28 via an RS232 port or a modem, using software to read the data into the computer. The obtained data can then be displayed on the computer as numerical data or as graphs. This data can also be used in other Windows programs such as MS Excel, making it convenient to use.

Connecting to a computer via the Internet (MC331).

Motor operating time log. Light On/Off Time Log. Record the time when a system anomaly occurred.
Warranty: 
1 year
Specifications

Serial Interface

Serial Standards:

RS232 Connector RJ12

Distance:

RS232 Length 15 m.

Serial Parameter

Baud Rate:

19200

Data Bits:

8

Stop Bits:

1

Parity:

None

Digital Input

Number of Channel:

4 Channels

Sensor Type:

Dry Contact or NPN Open Collector

Dry Contact:

ON : Short to GND

OFF : Open

Recording

Storage Internal:

128 Kbytes

Recording Interval:

10 msec

Record Mode:

Stop when full

Recording by:

Button SW

Data Format:

Can be Exported to MS Excel

Data Capacity:

21,845 Records (4 Channels)

Power Requirements

Power Supply:

Battery 6.2 VDC @1 AH (Sanyo CR123A Lithium)

Power Consumption

Standby:

30 µA @ 6 VDC

Start Record:

500 µA @ 6 VDC

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W81 x H61 x D26 mm.

Warranty

Warranty Period:

1 year

Ordering
Ordering Information:  
Example ML28/128Kbytes
Packagelist

Package Checklist

1. ML28

2. RS-232 Cable

Downloads
Group Order
Data Logger: 
11

ML27: Data Logger

- 1 Channel Humidity

- 1 Channel Temperature

- Memory 64 Kbyte (Up to 256

  Kbyte)

- Data exportable to MS Excel

General Features and Benefits: 

1 Channel Humidity

1 Channel Temperature

Memory 64 Kbyte (Up to 256 Kbyte)

Data exportable to MS Excel

            Data Logger ML27 This is a compact data-logging device featuring built-in humidity and temperature sensors. It continuously records data-along with corresponding timestamps-to its internal memory. It is ideal for installation in locations where humidity and/or temperature monitoring is required, such as cold storage rooms, ovens, and delivery vehicles.

            Data stored in the ML27 can be retrieved by connecting a computer to the unit via an RS232 port or a modem, using dedicated software to transfer the data. The retrieved data can be displayed on the computer in either numerical or graphical formats. Furthermore, the data is compatible with other Windows-based applications-such as MS Excel-facilitating further calculations or report generation.

Connecting to a computer via Wireless (RC35).

Connecting to a computer via Ethernet (MC330).

Connecting to a computer via Internet (MC331).

Warranty: 
1 year
Specifications

Serial Interface

Serial Standards:

RS232 Connector RJ12

Distance:

RS232 Length 15 m.

Serial Parameter

Baud Rate:

19200

Data Bits:

8

Stop Bits:

1

Parity:

None

Input

Number of Channel:

2 Channels

Input Type:

Humidity, Temperature (Sensor SHT15)

Input Range:

Humidity (0 to 100 %RH)

Accuracy: ± 2% at 10 to 90 %RH

Temperature ((-)40 to 80 °C)

Accuracy: ± 1 °C

ADC Resolution:

12 Bits

Recording

Storage Internal:

64 Kbytes (256 Kbytes optional)

Recording Interval:

1 Sec to 18 Hours (Programmable)

Record Mode:

Stop when full or Roll Over

Recording by:

Button SW

Data Format:

Can be Exported to MS Excel

Data Capacity:

16,380 Records that 64 Kbytes (2 Channels)

Power Requirements

Power Supply:

Battery 6.2 VDC @1 AH (Sanyo CR123A Lithium)

Power Consumption

Standby:

30 µA @ 6 VDC

Start Record:

500 µA @ 6 VDC

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W81 x H61 x D26 mm.

Warranty

Warranty Period:

1 year

Ordering
Ordering Information: Specify Memory
Example ML27/64Kbytes
Packagelist

Package Checklist

1. ML27

2. RS-232 Cable

Downloads
Group Order
Data Logger: 
10

ML25: Data Logger

- 3 Channels A.C. Current

- Memory 64 Kbyte (Up to 256 Kbyte)

- Data exportable to MS Excel

General Features and Benefits: 

3 Channels A.C. Current

Memory 64 Kbyte (Up to 256 Kbyte)

Data exportable to MS Excel

            Data Logger ML25 This is a compact device designed to record 3-phase AC current measurements; the data is continuously stored in the device's internal memory, accompanied by the corresponding date and time of recording.

            Data recorded in the ML25 can be retrieved by connecting a computer to the unit via an RS232 port or a modem, using dedicated software to transfer the data. The retrieved data can be displayed on the computer in either numerical or graphical formats. Furthermore, the data is compatible with other Windows-based applications-such as MS Excel-facilitating further calculations or report generation.

Connecting to a computer via wireless (RC35).

Connecting to a computer via Ethernet (MC330).

Connecting to a computer via (MC331).

Warranty: 
1 year
Specifications

Serial Interface

Serial Standards:

RS232 Connector RJ12

Distance:

RS232 Length 15 m.

Serial Parameter

Baud Rate:

19200

Data Bits:

8

Stop Bits:

1

Parity:

None

Current Input

Number of Channel:

3 Channels

Input Type:

Current (AC)

Input Range:

0 to 5 A

ADC Resolution:

10 Bits

Accuaracy:

± 0.2 % of span

Recording

Storage Internal:

64 Kbytes (256 Kbytes optional)

Recording Interval:

1 Sec to 18 Hours (Programmable)

Record Mode:

Stop when full or Roll Over

Recording by:

Button SW

Data Format:

Can be Exported to MS Excel

Data Capacity:

10,920 Records that 64 Kbytes (3 Channels)

Power Requirements

Power Supply:

Battery 9 VDC

Power Consumption

Standby:

30 µA @ 9 VDC

Start Record:

500 µA @ 9 VDC

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W117 x H65 x D23 mm.

Warranty

Warranty Period:

1 year

Ordering
Ordering Information: Specify Memory
Example ML25/64Kbytes
Packagelist

Package Checklist

1. ML25

2. RS-232 Cable

Downloads
Group Order
Data Logger: 
9

Wireless Data Logger

Wireless Data Logger

8 Channels Expandable to 768 Channels

General Features and Benefits: 

Programmable Input Type

8 Analog Input Channels up to 768 Channels

RS-232, RS-485 Isolated

No Wiring (RF Link)

Wireless Data Logger Wireless Data Logger This device enables a PC to function as a data recorder by reading measurements from external sources-such as thermocouples, pressure, flow, voltage, and current sensors-without requiring physical wiring between the module and the computer, and then processing the measured data as follows:

 

1 ) Real Time Display

      - Displays measured values as real-time numerical data on the computer screen.

2 ) Real Time Trend Graph

      - Displays real-time measured values as trend graphs, allowing for the observation of value fluctuations over time.

3 ) Recorder File

      - Continuously records data in file format onto the hard disk, with date and time stamps accompanying every data entry.

      - Data stored in the file can be retrieved and displayed numerically, plotted as trend graphs, or printed.

      - Convert files for use with other programs, such as Microsoft Word and Excel.

อุปกรณ์ที่เกี่ยวข้อง

AI210: PC Based Recorder

EX24: Analog Expansion Module

RC45: Radio Modem

 

Warranty: 
5 years
Specifications

Analog Input

Number of Channel:

8 Channels up to 768 Channels

Input Type:

Programmable Input

Input Range:

Thermocouple (R, S, K, E, J, T, B)

RTD (PT100)

Voltage mVDC (0 to 100 mVDC)

Voltage (0 to 10, 0 to 5 VDC)

Current (0 to 20, 0 to 40 mA)

ADC Resolution:

16 Bits

Isolation:

Relay Isolated

Power Requirements

Power Supply:

110 VAC, 220 VAC

12 VDC, 24 VDC (Optional)

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Warranty

Warranty Period:

5 year

Downloads
Group Order
Data Logger: 
1.2

CL24A: Data Logger

- 1 Channel Analog Input (4-20 mA,

  0-10 VDC)

- 2 Channels Totalizer

- Memory 256 KByte

- Data exportable to MS Excel

General Features and Benefits: 

1 Channel Analog Input (4-20 mA, 0-10 VDC)

2 Channels Totalizer

Memory 256 KByte

Data exportable to MS Excel

             Data Logger CL24A เป็นอุปกรณ์ทำหน้าที่บันทึกข้อมูลค่าวัดขนาดเล็ก ทั้งค่า Analog และ Counter (Totalizer) โดยข้อมูลนี้จะถูกเก็บอย่างต่อเนื่องไว้ในหน่วยความจำภายในเครื่อง ซึ่งจะมีค่าวันและเวลาที่บันทึกไว้กำกับลงไปด้วย โดย Analog Input สามารถระบุย่านที่จะวัดได้ตั้งแต่ 4-20 mA, 1-5 VDC, 0-5 VDC, 0-10 VDC ส่วน Totalizer นั้นจะทำการนับจำนวน Pulse ที่เข้ามาและจะบันทึกค่านับทั้งหมดลงในหน่วยความจำด้วย

             การอ่านข้อมูลที่บันทึกอยู่ใน CL24A ทำได้โดยใช้เครื่องคอมพิวเตอร์เชื่อมต่อกับ CL24A ผ่านทาง RS-232 Port หรือ ผ่านทาง Modem โดยมีโปรแกรมช่วยในการอ่านข้อมูลเข้าคอมพิวเตอร์ ข้อมูลที่ได้จะนำมาแสดงผลบน คอมพิวเตอร์ในแบบตัวเลขหรือนำมาแสดงในรูปแบบกราฟได้ ข้อมูลนี้สามารถนำไปใช้ในโปรแกรมบน Windows อื่นๆ เช่น MS Excel, MS Word ซึ่งช่วยให้สะดวกในการนำข้อมูลไปทำการคำนวณเพิ่มเติมหรือจัดทำรายงานได้อีกด้วย

การเชื่อมต่อกับเครื่องคอมพิวเตอร์ผ่านทาง Wireless (RC35)

การเชื่อมต่อกับเครื่องคอมพิวเตอร์ผ่านทาง Ethernet (MC330)

การเชื่อมต่อกับเครื่องคอมพิวเตอร์ผ่านทาง Internet (MC331)

Warranty: 
1 year
Specifications

Serial Interface

Serial Standards:

RS232 Connector RJ12

Distance:

RS232 Length 15 m.

Serial Parameter

Baud Rate:

19200

Data Bits:

8

Stop Bits:

1

Parity:

None

Analog Input

Number of Channel:

1 Channel

Input Type:

Current, Voltage

Input Range:

Current (4 to 20 mA)

Voltage (0 to 5, 1 to 5, 0 to 10 VDC Optional)

ADC Resolution:

10 Bits

Accuracy:

± 0.2 % of span

Totalizer Input

Number of Channel:

2 Channels

Sensor Type:

NPN open collector or Dry contact

I/O Mode:

Even Counter

Dry Contact:

ON : Short to GND

OFF : Open

Counter Frequency:

maximum frequency 20 Hz

Minimum Pulse Width:

50 msec

Recording

Storage Internal:

256 Kbytes

Recording Interval:

1 Sec to 18 Hours (Programmable)

Record Mode:

Stop When Full or Roll Over

Recording by:

Magnetic Starter, DI Trig

Data Format:

Can be Exported to MS Excel

Data Capacity:

131,040 Records (3 Channels)

Power Requirements

Power Supply:

Lithium Battery 7.2 VDC@2.4 AH

(2 Year Life Time @ 15 Min. Interval Time)

Power Consumption

Standby:

30 µA @ 7 VDC

Start Record:

500 µA @ 7 VDC

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W95 x H65 x D55 mm.

Protection:

IP65

Warranty

Warranty Period:

5 year

Ordering
Ordering Information: Specify Input Rang
Example CL24A/256Kbytes/4-20mA
Packagelist

Package Checklist

1. CL24A

2. RS-232 Cable

3.Input Cable

Downloads
Group Order
Data Logger: 
14.1

RC52: Modbus Data Center

- Smart Phone, Tablet, PC. Real Time Monitoring

- Automatic Synchronous Database Server (MySQL, SQL Server)

- Interface RS232, RS485/422

- Easy Setting by Embedded Web Console

- Keep Data as Tag (Max. 128 tags Option)

- Support Modbus RTU, ASCII, TCP

- Data backup more than 1 Week

General Features and Benefits: 

Automatic Synchronous Database Server (MySQL, SQL Server)

Interface RS232, RS485/422

Online Monitoring

Easy Setting by Embedded Web Console

Keep Data as Tag (Max. 128 tags Option)

Support Modbus RTU, ASCII, TCP

Data backup more than 1 Week

            Modbus Data Center RC52 is device for collecting data from Field Devices such as PLC, Power Meter, Flow Meter, Analog Module, RTU etc. Device is communicated with MODBUS RTU/ASCII/TCP protocol, compatible with (Serial Port) RS-232, RS-485 and RS-422. All of collecting data will be saving as “data tag” which is similar to SCADA then data will be sent to database server (MySQL, SQL Server). Can view data simultaneously via Smart Phone, Tablet, PC.

 

Warranty: 
5 years
Specifications

Ethernet Interface

Speed:

10/100 Mbps, Full-duplex or Half-duplex, Auto MDI/MDIX

Connector:

RJ45

Standard:

10 Base-T/100 Base-T Standard

Transmission:

100 m.

Protocols:

MODBUS TCP (Max. 8 Connection), TCP/IP, UDP, DHCP, HTTP

Configuration:

Web Console

Serial Interface

Serial Standards:

RS232 Through D-Type 9 Pin Connecter

RS485/422 (Isolated) 5 Pin Terminal Block

Loading:

RS485/422 Max 32 Unit

Distance:

RS232 Length 15 m.

RS485/422 Length 1 Km.

Protocol:

Modbus RTU, ASCII

Serial Parameter

Baud Rate:

4800, 9600, 19200, 38400, 57600, 115200

Data Bits:

7, 8

Stop Bits:

1, 2

Parity:

None, Even, Odd

System Requirement

Web Server:

Apache, IIS

Script:

PHP

Database:

MySQL, SQL Server

Record

Storage Interface:

256 Mbytes

Data Capacity:

@ 1 Tag = 22,369,621 Records

@ 80 Tags = 818,400 Records

   Sampling 1 min. = 568 days

   Sampling 10 sec = 94 days

@ 128 Tags = 516,222 Records (Optional)

   Sampling 1 min = 358 Day

   Sampling 10 sec = 59 Day

Power Requirements

Power Supply:

12 to 24 VDC

Power Consumption

Standby:

120 mA @ 12 VDC (1.5 W)

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W30 x H122 x D98 mm.

Mounting:

DIN Rail

Warranty

Warranty Period:

5 Year

Ordering
Ordering Information: Specify Data Capacity
Example RC52/80 Tags
Packagelist

Package Checklist

1. RC52

2. LAN Cable

Downloads
Group Order
Data Logger: 
23
Data COM: 
13.2
Product Order: 
13.2

RC51: 3G Modbus Data Center

- Smart Phone, Tablet, PC. Real Time Monitoring

- Automatic Synchronous Database Server (MySQL, SQL Server)

- Built-in 3G Modem (UMTS/HSDPA)

- Easy Setting by Embedded Web Console

- Keep Data as Tag (Max. 128 tags Option)

- Support Modbus RTU, ASCII ,TCP

- Data backup more than 1 Week

General Features and Benefits: 

Smart Phone, Tablet, PC. Real Time Monitoring

Automatic Synchronous Database Server (MySQL, SQL Server)

Built-in 3G Modem (UMTS/HSDPA)

Easy Setting by Embedded Web Console

Keep Data as Tag (Max. 128 tags Option)

Support Modbus RTU, ASCII ,TCP

Data backup more than 1 Week

            3G Modbus Data Center RC51 is equipment for collecting data from field devices such as PLC, Power Meter, Flow Meter, Analog Module etc. which communicate via Modbus Protocol (RTU/ASCII/TCP). Data will be store as “Data Tag” similar to process of SCADA then send the data to computer server (MySQL, SQL Server) using UMTS/HSDPA Modem (3G Modem) connect with local provider of mobile phone such as AIS, DTAC, TRUE and TOT (Thailand mobile provider). Can view data simultaneously via Smart Phone, Tablet, PC.

 

RC51 Overview (Video)

Wisserv Utility

Warranty: 
5 years
Specifications

Cellular Interface

Frequency Bands:

FDD LTE: 800/850/900/1800/2100/2600 MHz

TDD LTE: 2300/2500/2600 MHz

WCDMA: 850/900/2100 MHz

GSM: 900/1800 MHz

LTE Version:

3GPP E-UTRA Release 10

Data Transfer (Max.):

FDD LTE: 150 Mbps (DL), 50 Mbps (UL)

TDD LTE: 130 Mbps (DL), 35 Mbps (UL)

DC-HSPA+: 42 Mbps (DL), 5.76 Mbps (UL)

UMTS: 384 Kbps (DL), 384 Kbps (UL)

TD-SCDMA: 4.2 Mbps (DL), 2.2 Mbps (UL)

EDGE: 236.8 Kbps (DL), 236.8 Kbps (UL)

GPRS: 85.6 Kbps (DL), 85.6 Kbps (UL)

Output power:

FDD LTE 1800: 3.21 W

TDD LTE 2600: 1.7 W

WCDMA 850: 2.69 W

GPRS 900: 2.1 W

EDGE 900: 1.66 W

Ethernet Interface

Speed:

10/100 Mbps, Full-duplex or Half-duplex, Auto MDI/MDIX

Connector:

RJ45

Standard:

10 Base-T/100 Base-T Standard

Transmission:

100 m.

Protocols:

MODBUS TCP (Max. 8 Connection), TCP/IP, UDP, DHCP, HTTP

Configuration:

Web Console

Serial Interface

Serial Standards:

RS-232 Through D-Type 9 Pin Connecter

RS485/422 (Isolated) 5 Pin Terminal Block

Loading:

RS485/422 Max 32 Unit

Distance:

RS232 Length 15 m.

RS485/422 Length 1 Km.

Protocol:

Modbus RTU, ASCII

Serial Parameter

Baud Rate:

4800, 9600, 19200, 38400, 57600, 115200

Data Bits:

7, 8

Stop Bits:

1, 2

Parity:

None, Even, Odd

System Requirement

Web Server:

Apache, IIS

Script:

PHP

Database:

MySQL, SQL Server

Record

Storage Interface:

256 Mbytes

Data Capacity:

@ 1 Tag = 22,369,621 Records

@ 80 Tags = 818,400 Records

   Sampling 1 min. = 568 days

   Sampling 10 sec = 94 days

@ 128 Tags = 516,222 Records (Optional)

   Sampling 1 min = 358 Day

   Sampling 10 sec = 59 Day

Power Requirements

Power Supply:

12 to 24 VDC

Power Consumption

Standby:

120 mA @ 12 VDC (1.5 W)

Upload Data:

200 mA @ 12 VDC (2.5 W)

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W30 x H122 x D98 mm.

Mounting:

DIN Rail

Warranty

Warranty Period:

5 Year

Ordering
Ordering Information: Specify Data Capacity
Example RC51/80 Tags
Packagelist

Package Checklist

1. RC51

2. Antenna

3. LAN Cable

Downloads
Group Order
Data Logger: 
22
Data COM: 
13.1
Product Order: 
13.1
Slideshow Number: 
5