Data Acquisition, MODBUS I/O Module (RS-232, RS-485)

AI300 : Analog Input Module

- 9 Programmable Analog Input Type 
   (Isolated)

- 8 Digital Input/Output Channels

- Digital Input can be Programmable
   (Status, Counter, Frequency,
   Quadrature Counter, etc.)

- Support Protocol MODBUS RTU / ASCII
   Command (RS485)

General Features and Benefits: 

9 Programmable Analog Input Type (Isolated)

8 Digital Input/Output Channels

Digital Input can be Programmable

(Status, Counter, Frequency, Quadrature Counter, etc.)

Support Protocol MODBUS RTU / ASCII Command (RS485)

            Analog Input Module AI300 is a device that can receive 9 Analog Input signals, 8 Digital Input channels and control 8 Digital Output channels. Can be connected via port. USB or RS485 port, users can develop programs on PC, PLC or Touch Screen to read. Input values and control Digital Output using the MODBUS ASCII/RTU or Wisco protocol. ASCII by AI300 can also be powered from a USB port.

            Analog Input can be programmed to be used with sensors such as Thermocouple, RTD, and Programmed to receive signals Voltage (0-125, 0-500 mVDC, 0-5, 0-10 VDC), Current (4-20 mA) etc.

            Digital Input can receive both Logic and Counter signals. Logic will show the “ON” or “OFF” for Counter can be programmed to be different types of Counters, such as showing total values. (Totalized) of the number of Input Pulse, record the Totalized value of Flow, rotational speed (RPM), Frequency (Hz), measure the distance of movement of the workpiece (Rotary Encoder), record the Kwh. value of electricity usage or timekeeping (Timer), etc.

Example of connection

Warranty: 
5 years
Specifications

USB Interface

Compliance:

USB 1.1/2.0/3.0

Connector:

USB Type C (Female)

Serial Interface

Serial Standards:

2 Port RS485 (Isolated) 2 Pin Terminal Block

Loading:

RS485 Max 32 Unit

Distance:

RS485 Length 1 Km.

Protocol:

MODBUS (ASCII, RTU) or Wisco ASCII

Support Software:

Node-RED, Citect, Wonderware, Lab View, iFix, Genesis, etc.

Serial Parameter

Baud Rate:

1200, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600, 115200

Data Bits:

7, 8

Stop Bits:

1, 2

Parity:

None, Even, Odd

Analog Input

Number of Channel:

9 Channels

Input Type:

Programmable Input

Thermocouple: R, S, K, E, J, T, B, N

RTD: PT100, PT1000, Cu10

Resistance: 0 to 100 Ω, 0 to 1 KΩ, 0 to 10 KΩ, 0 to 100 KΩ

Voltage: ± 0 to 125, ± 0 to 250, ± 0 to 500, ± 0 to 1000, ± 0 to 2000 mVDC

High Voltage: 0 to 5, 0 to 7.5, 0 to 10, 0 to 15, 0 to 30 VDC

Current: 4 to 20, ± 0 to 20, ± 0 to 40 mA

Input Impedance:

Voltage (mVDC): More Than 10 MΩ

High Voltage (VDC): Approx. 200 KΩ

Current (mA): Approx. 47 Ω

ADC Resolution:

16 Bits

Digital Input

Number of Channel:

8 Channels

Sensor Type:

Wet Contact or Dry Contact (Opto Isolated)

Wet Contact
(DI to COM):

ON: 10 to 30 VDC

OFF: <2.5 VDC

Dry Contact
(DI to GND):

ON: DI Short to GND

OFF: Open

Status Mode:

ON, OFF

Counter Mode:

Counter, Rate (RPM, Hz, L/min), Timer, Counter A + Counter B,

Counter A - Counter B, Direction, Preset/Reset, Run/Hold, Quadrature

Frequency Pulse:

Low: 0.01 Hz, High: 1 KHz

Minimum Pulse Width:

1 msec.

Digital Output

Number of Channel:

8 Channels

Output Type:

NPN Open Collector

Max. Current:

30 VDC @ 1 A

Power Requirements

Power Supply:

110 to 230 VAC

(12 to 35 VDC Optional)

Port USB:

4.5 to 5.5 VDC

Power Consumption

Operating:

12 VDC @ 160 mA (1.92 W)

5 VDC @ 250 mA (1.25 W)

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W160 x H90 x D60 mm.

Mounting:

DIN Rail

Warranty

Warranty Period:

5 Year

Ordering
Ordering Information: Specify Power Supply
Example AI300/110-230VAC
Packagelist

Package Checklist

1. AI300

2. USB Cable

Downloads
Group Order
Product Order: 
2
Slideshow Number: 
2

AI300 : Analog Input Module

- 9 Programmable Analog Input Type 
   (Isolated)

- 8 Digital Input/Output Channels

- Digital Input can be Programmable
   (Status, Counter, Frequency,
   Quadrature Counter, etc.)

- Support Protocol MODBUS RTU / ASCII
   Command (RS485)

General Features and Benefits: 

9 Programmable Analog Input Type (Isolated)

8 Digital Input/Output Channels

Digital Input can be Programmable

(Status, Counter, Frequency, Quadrature Counter, etc.)

Support Protocol MODBUS RTU / ASCII Command (RS485)

            Analog Input Module AI300 เป็นอุปกรณ์ที่สามารถรับสัญญาณ Analog Input ได้ 9 ช่อง, Digital Input 8 ช่อง และควบคุม Digital Output ได้ 8 ช่อง สามารถเชื่อมต่อผ่านทางพอร์ต USB หรือพอร์ต RS485 ผู้ใช้สามารถพัฒนาโปรแกรมบน PC, PLC หรือ จอ Touch Screen เพื่ออ่านค่า Input และควบคุม Digital Output โดยอาศัย Protocol MODBUS ASCII/RTU หรือ Wisco ASCII โดย AI300 สามารถใช้แหล่งจ่ายไฟจากพอร์ต USB ได้อีกด้วย

            Analog Input สามารถโปรแกรมให้ใช้ได้กับ Sensor เช่น Thermocouple, RTD รวมถึงโปรแกรมให้รับสัญญาณ Voltage (0-125, 0-500 mVDC, 0-5, 0-10 VDC), Current (4-20 mA) เป็นต้น

            Digital Input สามารถรับสัญญาณได้ทั้งแบบ Logic และ Counter โดย Logic จะแสดงการ “ON” หรือ “OFF” สำหรับ Counter สามารถโปรแกรมเป็น Counter ชนิดต่างๆได้ เช่น แสดงค่าผลรวม (Totalized) ของจำนวน Input Pulse, บันทึกค่า Totalized ของ Flow, ความเร็วรอบ (RPM), ความถี่ (Hz), วัดระยะการเคลื่อนที่ของชิ้นงาน (Rotary Encoder), บันทึกค่า Kwh. ของการใช้ไฟฟ้า หรือการจับเวลา (Timer) เป็นต้น

ตัวอย่างการต่อใช้งาน

Warranty: 
5 years
Specifications

USB Interface

Compliance:

USB 1.1/2.0/3.0

Connector:

USB Type C (Female)

Serial Interface

Serial Standards:

2 Port RS485 (Isolated) 2 Pin Terminal Block

Loading:

RS485 Max 32 Unit

Distance:

RS485 Length 1 Km.

Protocol:

MODBUS (ASCII, RTU) or Wisco ASCII

Support Software:

Node-RED, Citect, Wonderware, Lab View, iFix, Genesis, etc.

Serial Parameter

Baud Rate:

1200, 2400, 4800, 9600, 14400, 19200, 28800, 38400, 57600, 115200

Data Bits:

7, 8

Stop Bits:

1, 2

Parity:

None, Even, Odd

Analog Input

Number of Channel:

9 Channels

Input Type:

Programmable Input

Thermocouple: R, S, K, E, J, T, B, N

RTD: PT100, PT1000, Cu10

Resistance: 0 to 100 Ω, 0 to 1 KΩ, 0 to 10 KΩ, 0 to 100 KΩ

Voltage: ± 0 to 125, ± 0 to 250, ± 0 to 500, ± 0 to 1000, ± 0 to 2000 mVDC

High Voltage: 0 to 5, 0 to 7.5, 0 to 10, 0 to 15, 0 to 30 VDC

Current: 4 to 20, ± 0 to 20, ± 0 to 40 mA

Input Impedance:

Voltage (mVDC): More Than 10 MΩ

High Voltage (VDC): Approx. 200 KΩ

Current (mA): Approx. 47 Ω

ADC Resolution:

16 Bits

Digital Input

Number of Channel:

8 Channels

Sensor Type:

Wet Contact or Dry Contact (Opto Isolated)

Wet Contact
(DI to COM):

ON: 10 to 30 VDC

OFF: <2.5 VDC

Dry Contact
(DI to GND):

ON: DI Short to GND

OFF: Open

Status Mode:

ON, OFF

Counter Mode:

Counter, Rate (RPM, Hz, L/min), Timer, Counter A + Counter B,

Counter A - Counter B, Direction, Preset/Reset, Run/Hold, Quadrature

Frequency Pulse:

Low: 0.01 Hz, High: 1 KHz

Minimum Pulse Width:

1 msec.

Digital Output

Number of Channel:

8 Channels

Output Type:

NPN Open Collector

Max. Current:

30 VDC @ 1 A

Power Requirements

Power Supply:

110 to 230 VAC

(12 to 35 VDC Optional)

Port USB:

4.5 to 5.5 VDC

Power Consumption

Operating:

12 VDC @ 160 mA (1.92 W)

5 VDC @ 250 mA (1.25 W)

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W160 x H90 x D60 mm.

Mounting:

DIN Rail

Warranty

Warranty Period:

5 Year

Ordering
Ordering Information: Specify Power Supply
Example AI300/110-230VAC
Packagelist

Package Checklist

1. AI300

2. USB Cable

Downloads
Group Order
Product Order: 
2
Slideshow Number: 
2

DO100: Digital Output Module

- 16 Digital Output (Relay

  Contact)

– Protocol MODBUS or ASCII

  Command

- RS232, RS485 Isolated (1000 V)

General Features and Benefits: 

16 Digital Output (Relay Contact)

Protocol MODBUS or ASCII Command

RS232, RS485 Isolated (1000 V)

            Digital Output Module DO100 เป็นอุปกรณ์ที่มี Digital Output เป็น Relay Contact ทั้งหมด 16 ช่อง โดยส่งคำสั่งควบคุมผ่านทาง RS485 ทำให้สามารถใช้คอมพิวเตอร์ หรือ PLC เขียนโปรแกรมขึ้นมาควบคุม Output Relay ได้ ตัวอย่างการใช้งาน เช่น ควบคุมการ ON – OFF ของระบบไฟฟ้า, ควบคุมการทำงานของ Motor เป็นต้น

ควบคุมการทำงานอุปกรณ์ต่างๆผ่านทาง RS485

การเชื่อมต่อผ่านทาง Ethernet (MC330)

การเชื่อมต่อผ่านทาง Wireless (RC35)

การเชื่อมต่อผ่านทาง Internet (MC331)

Warranty: 
5 years
Specifications

Serial Interface

Serial Standards:

RS485 (Isolated) 2 Pin Terminal Block

Loading:

RS485 Max 32 Unit

Distance:

RS485 Length 1 Km.

Protocol:

MODBUS ASCII/RTU, Wisco ASCII

Support Software:

Citect, Wonderware, LAB View etc.

Serial Parameter

Baud Rate:

4800, 9600, 19200, 57600

Data Bits:

8

Stop Bits:

1

Parity:

None

Relay Output

Number of Channel:

16 Channels

Relay Type:

N.O., N.C. (Optional)

Contact Rating:

5 A @ 250 VAC

5 A @ 30 VDC

Power Requirements

Power Supply:

110 to 230 VAC

12 to 35 VDC Optional

Power Consumption

Operate:

330 mA @ 12 VDC (3.96 W)

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W160 x H91 x D61 mm

Mounting:

DIN Rail

Warranty

Warranty Period:

5 Year

Ordering
Ordering Information: Specify Power Supply
Example DO100/110-230VAC
Packagelist

Package Checklist

1. DO100

Downloads
Group Order
Product Order: 
7.1

DIO100: Digital Input/Output Module

- 16 Digital Input (Isolated

  1000 V)

- 8 Digital Output (Relay Contact)

- RS485 Isolated

General Features and Benefits: 

16 Digital Input (Isolated 1000 V)

8 Digital Output (Relay Contact)

RS485 Isolated

            Digital Input/Output Module DIO100 สามารถรับสัญญาณ Digital Input ได้ 16 ช่องและมี Digital Output เป็น Relay Contact อีก 8 ช่อง การควบคุม DIO100 สามารถ ทำได้โดยส่งคำสั่งควบคุมผ่านทาง RS485 ทำให้สามารถใช้เครื่องคอมพิวเตอร์หรือ PLC เขียนโปรแกรมควบคุม Input-Output ได้ ตัวอย่างการใช้งาน เช่น แสดงสภาวะการทำงานของเครื่องจักร สภาวะการเกิด Alarm หรือควบคุมการ ON-OFF โดยใช้คอมพิวเตอร์ หรือ PLC เป็นต้น

แสดงสถานะการทำงานและควบคุมการทำงานของอุปกรณ์ต่างๆผ่าน RS485

การเชื่อมต่อผ่านทาง Ethernet (MC330)

การเชื่อมต่อผ่านทาง Wireless (RC35)

การเชื่อมต่อผ่านทาง Internet (MC331)

Warranty: 
5 years
Specifications

Serial Interface

Serial Standards:

RS485 (Isolated) 2 Pin Terminal Block

Loading:

RS485 Max 32 Unit

Distance:

RS485 Length 1 Km.

Protocol:

MODBUS ASCII/RTU, Wisco ASCII

Support Software:

Citect, Wonderware, LAB View etc.

Serial Parameter

Baud Rate:

4800, 9600, 19200, 57600

Data Bits:

8

Stop Bits:

1

Parity:

None

Digital Input

Number of Channel:

16 Channels

Sensor Type:

Wet Contact or Dry Contact

Wet Contact (DI to COM):

ON : 12 to 24 VDC

OFF : 0 VDC

Dry Contact (DI to GND):

ON : Short to GND

OFF : Open

Isolation:

Opto Isolated

Relay Output

Number of Channel:

8 Channels

Relay Type:

N.O.

Contact Rating:

5 A @ 250 VAC

5 A @ 30 VDC

Power Requirements

Power Supply:

110 to 230 VAC

12 to 35 VDC (Optional)

Power Consumption

Operate:

30 mA @ 12 VDC (0.36 W)

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W160 x H91 x D62 mm

Mounting:

DIN Rail

Warranty

Warranty Period:

5 Year

Ordering
Ordering Information: Specify Power Supply
Example DIO100/110-230VAC 
Packagelist

Package Checklist

1. DIO100

Downloads
Group Order
Product Order: 
5.1

DI100: Digital Input Module


– 32 Digital Input (Opto Isolated)

– RS485 Isolated

– MODBUS Protocol

– DIN Rail Mounting

General Features and Benefits: 

32 Digital Input (Opto Isolated)

RS485 Isolated

MODBUS Protocol

DIN Rail Mounting

            Digital Input Module DI100 เป็นอุปกรณ์ที่รับสัญญาณ Digital Input ได้ทั้งหมด 32 ช่อง โดยสามารถอ่านสถานะของสัญญาณผ่านทาง RS485 ทำให้สามารถใช้ Computer, PLC, Touch Screen เขียนโปรแกรมขึ้นมาอ่านค่า Digital ได้ ตัวอย่างการใช้งาน เช่น แสดงสภาวะการทำงานของเครื่องจักร, แสดงสภาวะการเกิด Alarm, ขยายจำนวน Digital Input ของ PLC เป็นต้น

แสดงสถานะการทำงานของอุปกรณ์ต่างๆ

การเชื่อมต่อผ่านทาง Ethernet (MC330)

การเชื่อมต่อผ่านทาง Wireless (RC35)

การเชื่อมต่อผ่านทาง Internet (MC331)

Warranty: 
5 years
Specifications

Serial Interface

Serial Standards:

RS485 (Isolated) 2 Pin Terminal Block

Loading:

RS485 Max 32 Unit

Distance:

RS485 Length 1 Km.

Protocol:

MODBUS ASCII/RTU, Wisco ASCII

Support Software:

Citect, Wonderware, LAB View etc.

Serial Parameter

Baud Rate:

4800, 9600, 19200, 57600

Data Bits:

8

Stop Bits:

1

Parity:

None

Digital Input

Number of Channel:

32 Channels

Sensor Type:

Wet Contact or Dry Contact

Wet Contact (DI to COM):

ON: 12 to 24 VDC (220 VAC Optional)

OFF: 0 VDC

Dry Contact (DI to GND):

ON: Short to GND

OFF: Open

Isolation:

Opto Isolated

Power Requirements

Power Supply:

110 to 230 VAC

12 to 35 VDC (Optional)

Power Consumption

Operate:

80 mA @ 12 VDC (0.96 W)

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W160 x H91 x D62 mm

Mounting:

DIN Rail

Warranty

Warranty Period:

5 Year

Ordering
Ordering Information: Specify Digital Input, Power Supply
Example DI100/12-24VDC/110-230VAC
Packagelist

Package Checklist

1. DI100

Downloads
Group Order
Product Order: 
4.1

DP61: Big Digital Remote Display

- 7-Segment LED Display

- 6 Digits Display 100 mm.

- Ethernet LAN / WiFi Connection

- MODBUS TCP/IP Protocol

General Features and Benefits: 

7-Segment LED Display

6 Digits Display 100 mm.

Ethernet LAN / WiFi Connection

MODBUS TCP/IP Protocol

            Big Digital Remote Display DP61 เป็นอุปกรณ์แสดงผลด้วย LED 7-Segment โดยรับค่าจากอุปกรณ์ต่างผ่านทางพอร์ต Ethernet (LAN) หรือ WiFi (Wireless LAN) โดยอาศัยโปรโตคอล MODBUS TCP/IP ในการสื่อสาร
            DP61 จะมีโหมดการทำงาน 2 โหมด ดังนี้
1. Server Mode DP61 จะทำตัวเป็น Modbus TCP Server รอการเชื่อมต่อจากอุปกรณ์ที่เป็น Client เช่น อุปกรณ์ PLC, HMI หรือ โปรแกรมบนเครื่องคอมพิวเตอร์
2. Client Mode DP61 จะทำตัวเป็น Modbus TCP Client ทำการเชื่อมต่อไปยังอุปกรณ์ปลายทางที่เป็น Modbus TCP Server เช่น Power Meter, Flow Meter, Modbus I/O ฯลฯ

Server Mode


Client Mode

DP61 นำค่าจาก PLC มาแสดงผล

DP61 นำค่าจาก Power Meter มาแสดงผล ผ่านอุปกรณ์ Media Converter (MC320)

Warranty: 
5 years
Specifications

WLAN Interface

WLAN Standards:

802.11a/b/g/n

Receiver Sensitivity for 802.11a:

-91 dBm @ 6 Mbps, -74 dBm @ 54 Mbps

Receiver Sensitivity for 802.11b:

-92 dBm @ 1 Mbps, -84 dBm @ 11 Mbps

Receiver Sensitivity for 802.11g:

-91 dBm @ 6 Mbps, -73 dBm @ 54 Mbps

Receiver Sensitivity for 802.11n:

-89 dBm @ 6.5 Mbps (20 MHz)

-71 dBm @ 72.2 Mbps (20 MHz)

Transmission Distance:

Up to 100 Meters (In Open Areas)

Security:

WEP Open System, WEP Shared Key, WPA-PSK,

WPA2-PSK, WPA-PSK/WPA2-PSK Mixed Mode

Ethernet Interface

Speed:

10/100 Mbps, Full-duplex or

Half-duplex, Auto MDI/MDIX

Connector:

RJ45

Standard:

10 Base-T/100 Base-T Standard

Transmission:

100 m.

Protocols:

TCP/IP, DHCP, HTTP,

MODBUS TCP Server (1 Connection),

MODBUS TCP Client (1 Connection)

Configuration:

Web Console

Monitor

Display:

6 Digits, Height 100 mm. (7 - Segment)

Display Color:

Red (std)

Power Requirements

Power Supply:

85 to 230 VAC

(12 to 35 VDC Optional)

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W590 x H140 x D60 mm.

Mounting:

Wall Mount

Warranty

Warranty Period:

5 Year

Ordering
Ordering Information: Specify Power Supply
Example DP61/220 VAC
Packagelist

Package Checklist

1. DP61

2. LAN Cable

3. Antenna

Downloads
Datasheet: 
Group Order
Big Digital Display: 
5.1
Product Order: 
11.1

RC52: Modbus Data Center

- Smart Phone, Tablet, PC. Real Time Monitoring

- Automatic Synchronous Database Server (MySQL, SQL Server)

- Interface RS232, RS485/422

- Easy Setting by Embedded Web Console

- Keep Data as Tag (Max. 128 tags Option)

- Support Modbus RTU, ASCII, TCP

- Data backup more than 1 Week

General Features and Benefits: 

Automatic Synchronous Database Server (MySQL, SQL Server)

Interface RS232, RS485/422

Online Monitoring

Easy Setting by Embedded Web Console

Keep Data as Tag (Max. 128 tags Option)

Support Modbus RTU, ASCII, TCP

Data backup more than 1 Week

            Modbus Data Center RC52 is device for collecting data from Field Devices such as PLC, Power Meter, Flow Meter, Analog Module, RTU etc. Device is communicated with MODBUS RTU/ASCII/TCP protocol, compatible with (Serial Port) RS-232, RS-485 and RS-422. All of collecting data will be saving as “data tag” which is similar to SCADA then data will be sent to database server (MySQL, SQL Server). Can view data simultaneously via Smart Phone, Tablet, PC.

 

Warranty: 
5 years
Specifications

Ethernet Interface

Speed:

10/100 Mbps, Full-duplex or Half-duplex, Auto MDI/MDIX

Connector:

RJ45

Standard:

10 Base-T/100 Base-T Standard

Transmission:

100 m.

Protocols:

MODBUS TCP (Max. 8 Connection), TCP/IP, UDP, DHCP, HTTP

Configuration:

Web Console

Serial Interface

Serial Standards:

RS232 Through D-Type 9 Pin Connecter

RS485/422 (Isolated) 5 Pin Terminal Block

Loading:

RS485/422 Max 32 Unit

Distance:

RS232 Length 15 m.

RS485/422 Length 1 Km.

Protocol:

Modbus RTU, ASCII

Serial Parameter

Baud Rate:

4800, 9600, 19200, 38400, 57600, 115200

Data Bits:

7, 8

Stop Bits:

1, 2

Parity:

None, Even, Odd

System Requirement

Web Server:

Apache, IIS

Script:

PHP

Database:

MySQL, SQL Server

Record

Storage Interface:

256 Mbytes

Data Capacity:

@ 1 Tag = 22,369,621 Records

@ 80 Tags = 818,400 Records

   Sampling 1 min. = 568 days

   Sampling 10 sec = 94 days

@ 128 Tags = 516,222 Records (Optional)

   Sampling 1 min = 358 Day

   Sampling 10 sec = 59 Day

Power Requirements

Power Supply:

12 to 24 VDC

Power Consumption

Standby:

120 mA @ 12 VDC (1.5 W)

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W30 x H122 x D98 mm.

Mounting:

DIN Rail

Warranty

Warranty Period:

5 Year

Ordering
Ordering Information: Specify Data Capacity
Example RC52/80 Tags
Packagelist

Package Checklist

1. RC52

2. LAN Cable

Downloads
Group Order
Data Logger: 
23
Data COM: 
13.2
Product Order: 
13.2

RC51: 3G Modbus Data Center

- Smart Phone, Tablet, PC. Real Time Monitoring

- Automatic Synchronous Database Server (MySQL, SQL Server)

- Built-in 3G Modem (UMTS/HSDPA)

- Easy Setting by Embedded Web Console

- Keep Data as Tag (Max. 128 tags Option)

- Support Modbus RTU, ASCII ,TCP

- Data backup more than 1 Week

General Features and Benefits: 

Smart Phone, Tablet, PC. Real Time Monitoring

Automatic Synchronous Database Server (MySQL, SQL Server)

Built-in 3G Modem (UMTS/HSDPA)

Easy Setting by Embedded Web Console

Keep Data as Tag (Max. 128 tags Option)

Support Modbus RTU, ASCII ,TCP

Data backup more than 1 Week

            3G Modbus Data Center RC51 is equipment for collecting data from field devices such as PLC, Power Meter, Flow Meter, Analog Module etc. which communicate via Modbus Protocol (RTU/ASCII/TCP). Data will be store as “Data Tag” similar to process of SCADA then send the data to computer server (MySQL, SQL Server) using UMTS/HSDPA Modem (3G Modem) connect with local provider of mobile phone such as AIS, DTAC, TRUE and TOT (Thailand mobile provider). Can view data simultaneously via Smart Phone, Tablet, PC.

 

RC51 Overview (Video)

Wisserv Utility

Warranty: 
5 years
Specifications

Cellular Interface

Frequency Bands:

FDD LTE: 800/850/900/1800/2100/2600 MHz

TDD LTE: 2300/2500/2600 MHz

WCDMA: 850/900/2100 MHz

GSM: 900/1800 MHz

LTE Version:

3GPP E-UTRA Release 10

Data Transfer (Max.):

FDD LTE: 150 Mbps (DL), 50 Mbps (UL)

TDD LTE: 130 Mbps (DL), 35 Mbps (UL)

DC-HSPA+: 42 Mbps (DL), 5.76 Mbps (UL)

UMTS: 384 Kbps (DL), 384 Kbps (UL)

TD-SCDMA: 4.2 Mbps (DL), 2.2 Mbps (UL)

EDGE: 236.8 Kbps (DL), 236.8 Kbps (UL)

GPRS: 85.6 Kbps (DL), 85.6 Kbps (UL)

Output power:

FDD LTE 1800: 3.21 W

TDD LTE 2600: 1.7 W

WCDMA 850: 2.69 W

GPRS 900: 2.1 W

EDGE 900: 1.66 W

Ethernet Interface

Speed:

10/100 Mbps, Full-duplex or Half-duplex, Auto MDI/MDIX

Connector:

RJ45

Standard:

10 Base-T/100 Base-T Standard

Transmission:

100 m.

Protocols:

MODBUS TCP (Max. 8 Connection), TCP/IP, UDP, DHCP, HTTP

Configuration:

Web Console

Serial Interface

Serial Standards:

RS-232 Through D-Type 9 Pin Connecter

RS485/422 (Isolated) 5 Pin Terminal Block

Loading:

RS485/422 Max 32 Unit

Distance:

RS232 Length 15 m.

RS485/422 Length 1 Km.

Protocol:

Modbus RTU, ASCII

Serial Parameter

Baud Rate:

4800, 9600, 19200, 38400, 57600, 115200

Data Bits:

7, 8

Stop Bits:

1, 2

Parity:

None, Even, Odd

System Requirement

Web Server:

Apache, IIS

Script:

PHP

Database:

MySQL, SQL Server

Record

Storage Interface:

256 Mbytes

Data Capacity:

@ 1 Tag = 22,369,621 Records

@ 80 Tags = 818,400 Records

   Sampling 1 min. = 568 days

   Sampling 10 sec = 94 days

@ 128 Tags = 516,222 Records (Optional)

   Sampling 1 min = 358 Day

   Sampling 10 sec = 59 Day

Power Requirements

Power Supply:

12 to 24 VDC

Power Consumption

Standby:

120 mA @ 12 VDC (1.5 W)

Upload Data:

200 mA @ 12 VDC (2.5 W)

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W30 x H122 x D98 mm.

Mounting:

DIN Rail

Warranty

Warranty Period:

5 Year

Ordering
Ordering Information: Specify Data Capacity
Example RC51/80 Tags
Packagelist

Package Checklist

1. RC51

2. Antenna

3. LAN Cable

Downloads
Group Order
Data Logger: 
22
Data COM: 
13.1
Product Order: 
13.1
Slideshow Number: 
5

HT21: Humidity & Temperature

- 2 Rows LCD Display

- 1 Humidity Channel

- 1 Temperature Channel

- 1 Dew Point Channel

- Communication Modbus Protocol ASCII and RTU

- Protection IP65

General Features and Benefits: 

2 Rows LCD Display

1 Humidity Channel

1 Temperature Channel

1 Dew Point Channel

Communication Modbus Protocol ASCII and RTU

Protection IP65

            Humidity & Temperature HT21 is record temperature and humidity via RS-485 communication port using Protocol Modbus ASCII and Protocol Modbus RTU with 2 rows LCD display

Note: HT21 can be communicate to Lab View, Fix, Genesis, etc.

Connection via Wireless (Point to Multipoint)

Connection via PLC

Connection via Touch Screen

Warranty: 
1 year
Specifications

Serial Interface

Serial Standards:

RS485 (Isolated) 2 Pin Terminal Block

Loading:

RS485 Max 32 Unit

Distance:

RS485 Length 1 Km.

Protocol:

MODBUS ASCII/RTU

Support Software:

Citect, Wonderware, LAB View etc.

Serial Parameter

Baud Rate:

4800, 9600, 19200, 57600

Data Bit:

8

Stop Bit:

1

Parity:

None

Input

Number of channel:

2 Channels

Input type:

Humidity, Temperature

Input range:

Humidity 0 to 100 %RH

Accuracy: ± 2% at 10 to 90 %RH.

Temperature (-)20 to 55 °C

Accuracy: ± 1 °C

Dew Point:

1 Channel

Power Requirements

Power Supply:

12 to 24 VDC

Power Consumption

Standby:

180 mA @ 12 VDC

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W95 x H65 x D55 mm

Probe Length:

Dia 11 x Length 20 mm.

Protection:

IP65

Warranty

Warranty Period:

1 Year

Ordering
Ordering Information:  
Example HT21
Packagelist

Package Checklist

1. HT21

Downloads
Group Order
Product Order: 
12.1

HT20: Humidity & Temperature To RS485 (Modbus)

- 1 Humidity Channel

- 1 Temperature Channel

- 1 Dew Point Channel

- Communication Modbus Protocol ASCII

  and RTU

General Features and Benefits: 

1 Humidity Channel

1 Temperature Channel

1 Dew Point Channel

Communication Modbus Protocol ASCII and RTU

            Humidity & Temperature To RS485 (Modbus) HT20 is record temperature and humidity via RS-485 communication port using Protocol Modbus ASCII and Protocol Modbus RTU

Note: HT20 can be communicate to Lab View, Fix, Genesis, etc.

Connection via Wireless (Point to Multipoint)

Connection via PLC

Connection via Touch Screen

Warranty: 
1 year
Specifications

Serial Interface

Serial Standards:

RS485 (Isolated) 2 Pin Terminal Block

Loading:

RS485 Max 32 Unit

Distance:

RS485 Length 1 Km.

Protocol:

MODBUS ASCII/RTU

Support Software:

Citect, Wonderware, LAB View etc.

Serial Parameter

Baud Rate:

4800, 9600, 19200, 57600

Data Bit:

8

Stop Bit:

1

Parity:

None

Input

Number of channel:

2 Channels

Input type:

Humidity, Temperature

Input range:

Humidity (0-100%)

Accuracy: ± 2% at 10 to 90 %RH.

Temperature (-)20 to 55 °C

Accuracy: ± 1 °C

Dew Point:

1 Channel

Power Requirements

Power Supply:

12 to 24 VDC

Power Consumption

Standby:

45 mA @ 12 VDC

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W95 x H65 x D55 mm

Probe Length:

Dia13 x Length33 mm.

Protection:

IP67

Warranty

Warranty Period:

1 Year

Ordering
Ordering Information:  
Example HT20
Packagelist

Package Checklist

1. HT20

Downloads
Group Order
Product Order: 
12
Syndicate content