Data Communications

RC52: Modbus Data Center

- Smart Phone, Tablet, PC. Real Time Monitoring

- Automatic Synchronous Database Server

- Interface RS232, RS485/422

- Easy Setting by Embedded Web Console

- Keep Data as Tag (Max. 128 tags Option)

- Support Modbus RTU, ASCII, TCP

- Data backup more than 1 Week

General Features and Benefits: 

Automatic Synchronous Database Server

Interface RS232, RS485/422

Online Monitoring

Easy Setting by Embedded Web Console

Keep Data as Tag (Max. 128 tags Option)

Support Modbus RTU, ASCII, TCP

Data backup more than 1 Week

            Modbus Data Center RC52 is device for collecting data from Field Devices such as PLC, Power Meter, Flow Meter, Analog Module, RTU etc. Device is communicated with MODBUS RTU/ASCII/TCP protocol, compatible with (Serial Port) RS-232, RS-485 and RS-422. All of collecting data will be saving as “data tag” which is similar to SCADA then data will be sent to database server. Can view data simultaneously via Smart Phone, Tablet, PC.

 

Warranty: 
5 years
Specifications

Ethernet Interface

Speed:

10/100 Mbps, Full-duplex or Half-duplex, Auto MDI/MDIX

Connector:

RJ45

Standard:

10 Base-T/100 Base-T Standard

Transmission:

100 m.

Protocols:

MODBUS TCP (Max. 4 Connection), TCP/IP, UDP, DHCP, HTTP

Configuration:

Web Console

Serial Interface

Serial Standards:

RS232 Through D-Type 9 Pin Connecter

RS485/422 (Isolated) 5 Pin Terminal Block

Loading:

RS485/422 Max 32 Unit

Distance:

RS232 Length 15 m.

RS485/422 Length 1 Km.

Protocol:

Modbus RTU, ASCII

Serial Parameter

Baud Rate:

4800, 9600, 19200, 38400, 57600, 115200

Data Bits:

7, 8

Stop Bits:

1, 2

Parity:

None, Even, Odd

System Requirement

Web Server:

Apache, IIS

Script:

PHP

Database:

MySQL, SQL Server

Record

Storage Interface:

256 Mbytes

Data Capacity:

@ 1 Tag = 22,369,621 Records

@ 80 Tags = 818,400 Records

   Sampling 1 min. = 568 days

   Sampling 10 sec = 94 days

@ 128 Tags = 516,222 Records (Optional)

   Sampling 1 min = 358 Day

   Sampling 10 sec = 59 Day

Power Requirements

Power Supply:

12 to 24 VDC

Power Consumption

Standby:

120 mA @ 12 VDC (1.5 W)

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W30 x H122 x D98 mm.

Mounting:

DIN Rail

Warranty

Warranty Period:

5 Year

Ordering
Ordering Information: Specify Data Capacity
Example RC52/80 Tags
Packagelist

Package Checklist

1. RC52

2. LAN Cable

3. Manual

4. CD Software

Downloads
Group Order
Data Logger: 
23
Data COM: 
13.2
Product Order: 
13.2

RC51: 3G Modbus Data Center

- Smart Phone, Tablet, PC. Real Time Monitoring

- Automatic Synchronous Database Server

- Built-in 3G Modem (UMTS/HSDPA)

- Easy Setting by Embedded Web Console

- Keep Data as Tag (Max. 128 tags Option)

- Support Modbus RTU, ASCII ,TCP

- Data backup more than 1 Week

General Features and Benefits: 

Smart Phone, Tablet, PC. Real Time Monitoring

Automatic Synchronous Database Server

Built-in 3G Modem (UMTS/HSDPA)

Easy Setting by Embedded Web Console

Keep Data as Tag (Max. 128 tags Option)

Support Modbus RTU, ASCII ,TCP

Data backup more than 1 Week

            3G Modbus Data Center RC51 is equipment for collecting data from field devices such as PLC, Power Meter, Flow Meter, Analog Module etc. which communicate via Modbus Protocol (RTU/ASCII/TCP). Data will be store as “Data Tag” similar to process of SCADA then send the data to computer server using UMTS/HSDPA Modem (3G Modem) connect with local provider of mobile phone such as AIS, DTAC, TRUE and TOT (Thailand mobile provider). Can view data simultaneously via Smart Phone, Tablet, PC.

 

RC51 Overview (Video)

Wisserv Utility

Warranty: 
5 years
Specifications

Cellular Interface

Dual Band:

UMTS/HSDPA (900/2100 MHz)

Quad Band:

GSM/GPRS/EDGE (850/900/1800/1900 MHz)

GPRS multi-slot:

Class 12

EDGE multi-slot:

Class 12

WCDMA 3GPP:

Release 5

Output power:

UMTS 850/1900: 0.25W

UMTS 900/2100: 0.25W

GSM 850/GSM 900: 2W

DCS 1800/PCS 1900: 1W

Data Transfer (Max.):

   HSDPA: 3.6 Mbps (DL)

   WCDMA: 384 Kbps (DL), 384 Kbps (UL)

   EDGE Class: 236.8 Kbps (DL), 118 Kbps (UL)

   GPRS: 85.6 Kbps (DL), 42.8 Kbps (UL)

   CSD: GSM data rate 14.4 Kbps

Ethernet Interface

Speed:

10/100 Mbps, Full-duplex or Half-duplex, Auto MDI/MDIX

Connector:

RJ45

Standard:

10 Base-T/100 Base-T Standard

Transmission:

100 m.

Protocols:

MODBUS TCP (Max. 4 Connection), TCP/IP, UDP, DHCP, HTTP

Configuration:

Web Console

Serial Interface

Serial Standards:

RS-232 Through D-Type 9 Pin Connecter

RS485/422 (Isolated) 5 Pin Terminal Block

Loading:

RS485/422 Max 32 Unit

Distance:

RS232 Length 15 m.

RS485/422 Length 1 Km.

Protocol:

Modbus RTU, ASCII

Serial Parameter

Baud Rate:

4800, 9600, 19200, 38400, 57600, 115200

Data Bits:

7, 8

Stop Bits:

1, 2

Parity:

None, Even, Odd

System Requirement

Web Server:

Apache, IIS

Script:

PHP

Database:

MySQL, SQL Server

Record

Storage Interface:

256 Mbytes

Data Capacity:

@ 1 Tag = 22,369,621 Records

@ 80 Tags = 818,400 Records

   Sampling 1 min. = 568 days

   Sampling 10 sec = 94 days

@ 128 Tags = 516,222 Records (Optional)

   Sampling 1 min = 358 Day

   Sampling 10 sec = 59 Day

Power Requirements

Power Supply:

12 to 24 VDC

Power Consumption

Standby:

120 mA @ 12 VDC (1.5 W)

Upload Data:

200 mA @ 12 VDC (2.5 W)

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W30 x H122 x D98 mm.

Mounting:

DIN Rail

Warranty

Warranty Period:

5 Year

Ordering
Ordering Information: Specify Data Capacity
Example RC51/80 Tags
Packagelist

Package Checklist

1. RC51

2. LAN Cable

3. Manual

4. CD Software

Downloads
Group Order
Data Logger: 
22
Data COM: 
13.1
Product Order: 
13.1

RC38: GSM Alarm

- 4 Analog Channels High-Low Alarm

- 2 Digital (Counter or Status) Alarm

- Programmable SMS Message

- Two Relay Output Control VIA SMS

- Read Out VIA SMS

- Built-in 3G Modem (UMTS/HSDPA)

General Features and Benefits: 

4 Analog Channels High-Low Alarm

2 Digital (Counter or Status) Alarm

Programmable SMS Message

Two Relay Output Control VIA SMS

Read Out VIA SMS

Built-in 3G Modem (UMTS/HSDPA)

            GSM Alarm RC38 When alarm happen RC38 will send SMS to the destination which was pre programmed. The alarm conditions as the following
            1. Analog Input Alarm Each analog input can program 2 alarm levels.
            2. Digital Input Alarm When digital input change status
           3. More than this we can send SMS to comtrol (on - off) 2 internal relays of RC38. And can send SMS to read the value of analog input



 

Example of SMS Report

Warranty: 
5 years
Specifications

Cellular Interface

Dual Band:

UMTS/HSDPA (900/2100 MHz)

Quad Band:

GSM/GPRS/EDGE (850/900/1800/1900 MHz)

GPRS multi-slot:

Class 12

EDGE multi-slot:

Class 12

WCDMA 3GPP:

Release 5

Output power:

UMTS 850/1900: 0.25W

UMTS 900/2100: 0.25W

GSM 850/GSM 900: 2W

DCS 1800/PCS 1900: 1W

Data Transfer (Max.):

   HSDPA: 3.6 Mbps (DL)

   WCDMA: 384 Kbps (DL), 384 Kbps (UL)

   EDGE Class: 236.8 Kbps (DL), 118 Kbps (UL)

   GPRS: 85.6 Kbps (DL), 42.8 Kbps (UL)

   CSD: GSM data rate 14.4 Kbps

USB Interface

Compliance:

USB 1.1/2.0

Connector:

USB Type B

Speed:

12 Mbps (Full-Speed USB)

Class:

CDC

Operating System:

Windows 98/SE, ME, NT, 2000, XP, Vista, 7, 8, 10 (32 and 64 Bit)

Analog Input

Number of channel:

4 channels

Input type:

Current, Voltage

Input range:

Current (4 to 20 mA)

Voltage mVDC (0 to 100 mVDC)

Voltage (0 to 5, 1 to 5, 0 to 10 VDC)

ADC Resolution:

16 Bits

Digital Input

Digital Channel:

2 channels

Sensor Type:

NPN open collector or Dry Contact

I/O Mode:

DI or Even Counter

Dry Contact:

ON : Short to GND

OFF : Open

Counter Frequency:

Max 20 Hz

Minimum Pulse Width:

50 ms

Accuaracy:

± 0.2 % of span

Relay Output

Number of Channel:

2 Channels

Relay Type:

N.O. or N.C.

Contact Rating:

6 A @ 250 VAC

6 A @ 30 VDC

Power Requirements

Power Supply:

12 to 24 VDC

Power Consumption

Standby:

90 mA @ 12 VDC

Start Record:

110 mA @ 12 VDC

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W100 x H123 x D30 mm.

Mounting:

Screw

Warranty

Warranty Period:

5 Year

Ordering
Ordering Information: Specify input range
Example RC38/12-24 VDC/4-20mA
Packagelist

Package Checklist

1. RC38

2. Antenna

3. USB Cable

4. Manual

5. CD-Software

Downloads
Group Order
Data COM: 
11
Alarm Module: 
7.2

RC37: GSM Alarm

- 8 Alarm Digital inputs

- Programmable SMS Message

- Buffer 32 Alarm (Network Fail 15 Minute)

- 2 Digital Output Controlled by SMS

- Built-in 3G Modem (UMTS/HSDPA)

General Features and Benefits: 

8 Alarm Digital inputs

Programmable SMS Message

Buffer 32 Alarm (Network Fail 15 Minute)

2 Digital Output Controlled by SMS

Built-in 3G Modem (UMTS/HSDPA)

            GSM Alarm RC37 When the digital input change status RC37 will send SMS. The message of SMS and tel. number can be programmed by software. We can send SMS to control internal relays of RC37


ตัวอย่างการต่อใช้งาน

Example of SMS Report

Examples of cold room alarm applications

Warranty: 
5 years
Specifications

Cellular Interface

Frequency Bands:

FDD LTE: 800/850/900/1800/2100/2600 MHz

TDD LTE: 2300/2500/2600 MHz

WCDMA: 850/900/2100 MHz

GSM: 900/1800 MHz

LTE Version:

3GPP E-UTRA Release 10

Data Transfer (Max.):

FDD LTE: 150 Mbps (DL), 50 Mbps (UL)

TDD LTE: 130 Mbps (DL), 35 Mbps (UL)

DC-HSPA+: 42 Mbps (DL), 5.76 Mbps (UL)

UMTS: 384 Kbps (DL), 384 Kbps (UL)

TD-SCDMA: 4.2 Mbps (DL), 2.2 Mbps (UL)

EDGE: 236.8 Kbps (DL), 236.8 Kbps (UL)

GPRS: 85.6 Kbps (DL), 85.6 Kbps (UL)

Output power:

FDD LTE 1800: 3.21 W

TDD LTE 2600: 1.7 W

WCDMA 850: 2.69 W

GPRS 900: 2.1 W

EDGE 900: 1.66 W

USB Interface

Compliance:

USB 1.1/2.0

Connector:

USB Type B

Speed:

12 Mbps (Full-Speed USB)

Class:

CDC

Operating System:

Windows 98/SE, ME, NT, 2000, XP, Vista, 7, 8, 10 (32 and 64 Bit)

Digital Input

Number of channel:

8 Channels

Sensor Type:

Dry Contact

Dry Contact:

ON : Short to GND

OFF : Open

Relay Output

Number of Channel:

2 Channels

Relay Type:

N.O.

Contact Rating:

6 A @ 250 VAC

6 A @ 30 VDC

Power Requirements

Power Supply:

110 VAC, 220 VAC

12 VDC, 24 VDC (Optional)

Consumption:

110 mA @ 24 VDC (2.7 VA)

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W122 x H30 x D120 mm.

Mounting:

Screw

Warranty

Warranty Period:

5 Year

Ordering
Ordering Information: Specify Power Supply
Example RC37/220VAC
Packagelist

Package Checklist

1. RC37

2. Antenna

3. USB Cable

4. Manual

5. CD Software

Downloads
Group Order
Data COM: 
10
Alarm Module: 
7.1

RC33: RS-232/RS-485/RS-422 To Ethernet Converter

- Control Serial Device over Ethernet

- 10/100 Mbps Ethernet Interface

- Distance Serial Connections

General Features and Benefits: 

Control Serial Device over Ethernet

10/100 Mbps Ethernet Interface

Distance Serial Connections

            RS-232/RS-485/RS-422 to Ethernet Converter RC33 is device for convert serial communication (RS232/RS485) to Ethernet without changing any software. RC33 is compatible with any software since it does not change protocol instead it using Ethernet Network to transfer data so there is no need to wiring a cable.

            There are three working mode of RC33
            - Direct IP Mode ตัว RC33 RC33 acting as TCP or UDP Server so other equipment the Lan Network can be connect to RC33 using remote IP address
            - Virtual COM Mode simulate COM Port using software to connect to RC33
            - Paired Mode Connecting 2 device which have serial port via Lan Network Simple as picture below

Connecting example

 


Connecting PLC via Internet network

 


Connecting Computer and PLC via Internet Network



ตัวอย่าง "การตั้งค่าการใช้งาน"

Warranty: 
5 years
Specifications

Ethernet Interface

Speed:

10/100 Mbps, Full-duplex or half-duplex, Auto MDI/MDIX

Connector:

RJ45 (10 Base-T) Ethernet

Standard:

Accord 10 Base-T/100 Base-T standard

Data Rates:

300 - 115,200 bps

Transmission:

100 m.

Magnetic Isolation Protection:

15 KV Built-in

Serial Interface

Serial Standards:

RS-232 through D-Type 9 pin connecter

RS485/422 (Isolated) 4 Pin Terminal Block

Loading:

RS485/422 Max 32 Unit

Distance:

RS232 Length 15 m.

RS485/422 Length 1 Km.

Serial Parameter

Baud Rate:

4800, 9600, 19200, 38400, 57600, 115200

Data Bits:

7, 8

Stop Bits:

1, 2

Parity:

None, Even, Odd

Flow Control:

None, XonXoff, Hardware

Power Requirements

Power Supply:

110 VAC, 220 VAC

24 VDC (Optional)

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

w122 x H30 x D120 mm.

Warranty

Warranty Period:

5 Year

Ordering
Ordering Information: Power Supply
Example RC33/220VAC
Packagelist

Package Checklist

1. RC33

2. LAN Cable

3. USB Cable

4. Manual

5. CD Software

Downloads
Group Order
Data COM: 
2

RC32: Modbus Gateway

- Convert between Modbus TCP and Modbus

  RTU/ASCII

- 1 Ethernet port and 1 RS-232, RS422/485

  ports

- Supports 8 TCP MODBUS Protocol Device

  and 32 MODBUS Serial Connection

- Easy hardware setup and configuration

General Features and Benefits: 

Convert between Modbus TCP and Modbus RTU/ASCII

1 Ethernet port and 1 RS-232, RS422/485 ports

Supports 8 TCP MODBUS Protocol Device and 32 MODBUS Serial Connection

Easy hardware setup and configuration

      Modbus Gateway RC32 is communication device between Modbus TCP and Modbus RTU/ASCll. RC32 can connect to serial no matter it is Master or Slave, for Ethernet it can connect as Master or Client (Modbus TCP Master, Modbus TCP Slave). One Master can be connecting to 8 clients simultaneously. RC32 is set up by PC Program.

Warranty: 
5 years
Specifications

Ethernet Interface

Speed:

10/100 Mbps, Full-duplex or half-duplex, Auto MDI/MDIX

Connector:

RJ45 (10 Base-T) Ethernet

Standard:

Accord 10 Base-T/100 Base-T standard

Data Rates:

300 - 115,200 bps

Transmission:

100 m.

Magnetic Isolation Protection:

15 KV Built-in

Protocols:

MODBUS TCP

Serial Interface

Serial Standards:

RS232 Connector DB9 Male

RS485/422 (Isolated) 4 Pin Terminal Block

Loading:

RS485/422 Max 32 Unit

Distance:

RS232 Length 15 m.

RS485/422 Length 1 Km.

Protocol:

MODBUS ASCII/RTU

Support Software:

Citect, Wonderware, LAB View etc.

Serial Parameter

Baud Rate:

4800, 9600, 19200, 38400, 57600, 115200

Data Bits:

7, 8

Stop Bits:

1, 2

Parity:

None, Even, Odd

Software

Operation Mode:

RTU Slave, RTU Master, ASCll Slave, ASCll Master

Multi Master and Multi drop

Master Mode:

8 Connection

Slave Mode:

8 Connection

Power Requirements

Power Supply:

220 VAC

12 VDC, 24 VDC (Optional)

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W50 x H70 x D130 mm.

Mounting:

Wall or DIN rail

Connection:

Plug-in 11 pins socket

Housing:

Plastic

Warranty

Warranty Period:

5 Year

Ordering
Ordering Information: Power Supply
Example RC32/220 VAC
Packagelist

Package Checklist

1. RC32

2. LAN Cable

3. Manual

4. CD Software

Downloads
Group Order
Data COM: 
1
SUB Product Order: 
14

RC52: Modbus Data Center

-Smart Phone, Tablet, PC. Real Time Monitoring

- Automatic Synchronous Database Server

- Interface RS232, RS485/422

- Easy Setting by Embedded Web Console

- Keep Data as Tag (Max. 128 tags Option)

- Support Modbus RTU, ASCII, TCP

- Data backup more than 1 Week

General Features and Benefits: 

Smart Phone, Tablet, PC. Real Time Monitoring

Automatic Synchronous Database Server

Interface RS232, RS485/422

Easy Setting by Embedded Web Console

Keep Data as Tag (Max. 128 tags Option)

Support Modbus RTU, ASCII, TCP

Data backup more than 1 Week

            Modbus Data Center RC52 เป็นอุปกรณ์ที่ถูกออกแบบมาเพื่อทำหน้ารวบรวมข้อมูลจากอุปกรณ์ภาคสนาม (Field Devices) เช่น PLC, Power Meter, Flow Meter, Analog Module, RTU ฯลฯ ที่สื่อสารด้วยโปรโตคอล MODBUS RTU/ASCII/TCP โดยการเก็บรวบรวมข้อมูลของอุปกรณ์ต่างๆไว้ในรูปของ “ป้ายข้อมูล (Data Tag)” คล้ายกับการทำงานของโปรแกรม SCADA และทำการส่งข้อมูลให้กับคอมพิวเตอร์เซิร์ฟเวอร์ เพื่อจัดเก็บลงฐานข้อมูล

 

RC52 Review (Video)

Wisserv Utility

Warranty: 
5 years
Specifications

Ethernet Interface

Speed:

10/100 Mbps, Full-duplex or Half-duplex, Auto MDI/MDIX

Connector:

RJ45

Standard:

10 Base-T/100 Base-T Standard

Transmission:

100 m.

Protocols:

MODBUS TCP (Max. 4 Connection), TCP/IP, UDP, DHCP, HTTP

Configuration:

Web Console

Serial Interface

Serial Standards:

RS232 Through D-Type 9 Pin Connecter

RS485/422 (Isolated) 5 Pin Terminal Block

Loading:

RS485/422 Max 32 Unit

Distance:

RS232 Length 15 m.

RS485/422 Length 1 Km.

Protocol:

Modbus RTU, ASCII

Serial Parameter

Baud Rate:

4800, 9600, 19200, 38400, 57600, 115200

Data Bits:

7, 8

Stop Bits:

1, 2

Parity:

None, Even, Odd

System Requirement

Web Server:

Apache, IIS

Script:

PHP

Database:

MySQL, SQL Server

Record

Storage Interface:

256 Mbytes

Data Capacity:

@ 1 Tag = 22,369,621 Records

@ 80 Tags = 818,400 Records

   Sampling 1 min. = 568 days

   Sampling 10 sec = 94 days

@ 128 Tags = 516,222 Records (Optional)

   Sampling 1 min = 358 Day

   Sampling 10 sec = 59 Day

Power Requirements

Power Supply:

12 to 24 VDC

Power Consumption

Standby:

120 mA @ 12 VDC (1.5 W)

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W30 x H122 x D98 mm.

Mounting:

DIN Rail

Warranty

Warranty Period:

5 Year

Ordering
Ordering Information: Specify Data Capacity
Example RC52/80 Tags
Packagelist

Package Checklist

1. RC52

2. LAN Cable

3. Manual

4. CD Software

Downloads
Datasheet: 
Group Order
Data Logger: 
23
Data COM: 
13.2
Product Order: 
13.2

RP24: RS485 Repeater

- Extend RS485 Distance

- 115.2 kbps Data Rate

- Galvanic Isolation

General Features and Benefits: 

Extend RS485 Distance

115.2 kbps Data Rate

Galvanic Isolation

            RS485 Repeater RP24 is designed as a robust repeater for industrial applications where galvanic isolation is important. It can be used to extend both the distance and number of nodes on RS485 (2-Wire) network. Galvanic Isolation helps eliminate noise and protects equipment from destructive transients found in industrial application.

DIP Switch Setting
SW ON OFF
1 - 2 Master A Slave A
3 - 4 Master B Slave B

Note: Built-In Terminate Resistance 120 Ω (Slave Mode)

Warranty: 
5 years
Specifications

Serial Interface

Serial Standards:

RS485 (Isolated)

Distance:

RS485 Up to 1.2 Km. on Each Side

Data Rate:

Up to 115.2 kbps

Operating Mode:

RS485 (2-Wire Half-Duplex)

Isolation:

Between Input, Output and Power Supply

Power Requirements

Power Supply:

110 VAC, 220 VAC

12 or 24 VDC (Optional)

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W50 x H70 x D130 mm

Mounting:

Wall or DIN Rail

Connection:

Plug-In 11 pins Socket

Warranty

Warranty Period:

5 Year

Ordering
Ordering Information: Specify Power Supply
Example RP24/220VAC
Packagelist

Package Checklist

1. RP24

Downloads
Datasheet: 
Group Order
Data COM: 
5.1

RC34: RS-232/RS-485/RS-422 To 3G Converter

- Control Serial Device over 3G

- Built-in 3G Modem (UMTS/HSDPA)

- 10/100Mbps Ethernet Interface

- Distance Serial Connections

- Compatible to regular SIM card

 

General Features and Benefits: 

Control Serial Device over 3G

Built-in 3G Modem (UMTS/HSDPA)

10/100Mbps Ethernet Interface

Distance Serial Connections

Compatible to regular SIM card

            RS-232/RS-485/RS-422 to 3G RC34 เป็นอุปกรณ์ที่ช่วยให้เครื่องมือที่มีพอร์ต RS-232 หรือ RS-485/RS-422 สามารถส่งข้อมูลผ่านทางเครือค่ายโทรศัพท์ 3G (Modem Built in) โดยยังคงสามารถใช้งานร่วมกับโปรแกรมของเดิมได้ ทำให้การใช้งานของอุปกรณ์สามารถเชื่อมต่อได้โดยไม่มีข้อจำกัดทาง Serial Port อีกต่อไป

            โหมดการใช้งานของ RC34 คือ Virtual COM Mode เมื่อต้องการใช้โปรแกรมบนเครื่องคอมพิวเตอร์เพื่อติดต่อผ่าน RC34 โดยใช้ 3G สามารถจำลอง COM Port ขึ้นมาแทน ทำให้ไม่ต้องใช้อุปกรณ์ที่เกี่ยวข้องกับ COM Port ทางฝั่งของเครื่องคอมพิวเตอร์เลย

 


 


การสื่อสารระหว่าง RC34 และ RC33

Warranty: 
5 years
Specifications

Cellular Interface

Dual Band:

UMTS/HSDPA (900/2100 MHz)

Quad Band:

GSM/GPRS/EDGE (850/900/1800/1900 MHz)

GPRS multi-slot:

Class 12

EDGE multi-slot:

Class 12

WCDMA 3GPP:

Release 5

Output power:

UMTS 850/1900: 0.25W

UMTS 900/2100: 0.25W

GSM 850/GSM 900: 2W

DCS 1800/PCS 1900: 1W

Data Transfer (Max.):

   HSDPA: 3.6 Mbps (DL)

   WCDMA: 384 Kbps (DL), 384 Kbps (UL)

   EDGE Class: 236.8 Kbps (DL), 118 Kbps (UL)

   GPRS: 85.6 Kbps (DL), 42.8 Kbps (UL)

   CSD: GSM data rate 14.4 Kbps

Ethernet Interface

Speed:

10/100 Mbps, Full-duplex or Half-duplex, Auto MDI/MDIX

Connector:

RJ45

Standard:

10 Base-T/100 Base-T Standard

Transmission:

100 m.

Serial Interface

Serial Standards:

RS-232 Through D-Type 9 Pin Connecter

RS485/422 (Isolated) 5 Pin Terminal Block

Loading:

RS485/422 Max 32 Unit

Distance:

RS232 Length 15 m.

RS485/422 Length 1 Km.

Serial Parameter

Baud Rate:

4800, 9600, 19200, 38400, 57600, 115200

Data Bits:

7, 8

Stop Bits:

1, 2

Parity:

None, Even, Odd

Power Requirements

Power Supply:

12 to 24 VDC

Power Consumption

Standby:

120 mA @ 12 VDC (1.5 W)

Upload Data:

200 mA @ 12 VDC (2.5 W)

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W30 x H122 x D98 mm.

Mounting:

DIN Rail

Warranty

Warranty Period:

5 Year

Ordering
Ordering Information:  
Example RC34
Packagelist

Package Checklist

1. RC34

2. LAN Cable

3. Manual

4. CD Software

Downloads
Datasheet: 
Group Order
Data COM: 
2.1

RC51: 3G Modbus Data Center

- Smart Phone, Tablet, PC. Real Time Monitoring

- Automatic Synchronous Database Server

- Built-in 3G Modem (UMTS/HSDPA)

- Easy Setting by Embedded Web Console

- Keep Data as Tag (Max. 128 tags Option)

- Support Modbus RTU, ASCII ,TCP

- Data backup more than 1 Week

General Features and Benefits: 

Smart Phone, Tablet, PC. Real Time Monitoring

Automatic Synchronous Database Server

Built-in 3G Modem (UMTS/HSDPA)

Easy Setting by Embedded Web Console

Keep Data as Tag (Max. 128 tags Option)

Support Modbus RTU, ASCII ,TCP

Data backup more than 1 Week

            3G Modbus Data Center RC51 เป็นอุปกรณ์ที่ทำหน้าที่รวบรวมข้อมูลจากอุปกรณ์ภาคสนาม (Field Devices) เช่น PLC, Power Meter, Flow Meter, Analog Module ฯลฯ ที่สื่อสารด้วยโปรโตคอล MODBUS RTU/ASCII/TCP โดยการเก็บรวบรวมข้อมูลของอุปกรณ์ต่างๆไว้ในรูปของ “ป้ายข้อมูล (Data Tag)” คล้ายกับการทำงานของโปรแกรม SCADA และทำการส่งข้อมูลให้กับเครื่องคอมพิวเตอร์เซิร์ฟเวอร์เพื่อจัดเก็บลงฐานข้อมูล โดยอาศัยโมเด็ม UMTS/HSDPA (3G Modem) ที่ถูกติดตั้งไว้ภายในตัว ผ่านเครือข่ายโทรศัพท์ไร้สายระบบ GSM ซึ่งมีผู้ให้บริการภายในประเทศหลายรายเช่น AIS, DTAC, TRUE, TOT ฯลฯ สามารถดูข้อมูลพร้อมกันผ่านทาง Smart Phone, Tablet หรือ PC ได้

 

RC51 Overview (Video)

Wisserv Utility

Warranty: 
5 years
Specifications

Cellular Interface

Dual Band:

UMTS/HSDPA (900/2100 MHz)

Quad Band:

GSM/GPRS/EDGE (850/900/1800/1900 MHz)

GPRS multi-slot:

Class 12

EDGE multi-slot:

Class 12

WCDMA 3GPP:

Release 5

Output power:

UMTS 850/1900: 0.25W

UMTS 900/2100: 0.25W

GSM 850/GSM 900: 2W

DCS 1800/PCS 1900: 1W

Data Transfer (Max.):

   HSDPA: 3.6 Mbps (DL)

   WCDMA: 384 Kbps (DL), 384 Kbps (UL)

   EDGE Class: 236.8 Kbps (DL), 118 Kbps (UL)

   GPRS: 85.6 Kbps (DL), 42.8 Kbps (UL)

   CSD: GSM data rate 14.4 Kbps

Ethernet Interface

Speed:

10/100 Mbps, Full-duplex or Half-duplex, Auto MDI/MDIX

Connector:

RJ45

Standard:

10 Base-T/100 Base-T Standard

Transmission:

100 m.

Protocols:

MODBUS TCP (Max. 4 Connection), TCP/IP, UDP, DHCP, HTTP

Configuration:

Web Console

Serial Interface

Serial Standards:

RS-232 Through D-Type 9 Pin Connecter

RS485/422 (Isolated) 5 Pin Terminal Block

Loading:

RS485/422 Max 32 Unit

Distance:

RS232 Length 15 m.

RS485/422 Length 1 Km.

Protocol:

Modbus RTU, ASCII

Serial Parameter

Baud Rate:

4800, 9600, 19200, 38400, 57600, 115200

Data Bits:

7, 8

Stop Bits:

1, 2

Parity:

None, Even, Odd

System Requirement

Web Server:

Apache, IIS

Script:

PHP

Database:

MySQL, SQL Server

Record

Storage Interface:

256 Mbytes

Data Capacity:

@ 1 Tag = 22,369,621 Records

@ 80 Tags = 818,400 Records

   Sampling 1 min. = 568 days

   Sampling 10 sec = 94 days

@ 128 Tags = 516,222 Records (Optional)

   Sampling 1 min = 358 Day

   Sampling 10 sec = 59 Day

Power Requirements

Power Supply:

12 to 24 VDC

Power Consumption

Standby:

120 mA @ 12 VDC (1.5 W)

Upload Data:

200 mA @ 12 VDC (2.5 W)

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W30 x H122 x D98 mm.

Mounting:

DIN Rail

Warranty

Warranty Period:

5 Year

Ordering
Ordering Information: Specify Data Capacity
Example RC51/80 Tags
Packagelist

Package Checklist

1. RC51

2. LAN Cable

3. Manual

4. CD Software

Downloads
Datasheet: 
Group Order
Data Logger: 
22
Data COM: 
13.1
Product Order: 
13.1
Syndicate content