Control module

HB20: Heater Break Relay

- Current Input (0-5 A, 0-10 A)

- Operating Mode Under or Over

General Features and Benefits: 

Current Input (0-5 A, 0-10 A)

Operating Mode Under or Over

Warranty: 
1 year
Specifications

Input

Number of channel:

1 Channel

Input type:

Current (AC)

Input range:

0 to 5, 0 to 10 A

Current Setpoint:

0 to 100 % of input range

Operating Mode:

Relay energized when Under Current

Relay Output

Number of channel:

1 Channel

Relay Type:

N.O. (SPDT)

Contact Rating:

5 A @ 250 VAC

Power Requirements

Power Supply:

220 VAC

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W65 x H65 x D32mm.

Warranty

Warranty Period:

1 Year

Ordering
Ordering Information: Specify Input
Example HB20/0-5 A
Packagelist

Package Checklist

1. HB20

Downloads
Group Order
Product Order: 
5

JP99: Jet Pulser

- ควบคุมการปิด - เปิด ของวาล์ว

- ตั้งเวลาการเปิดและปิดได้

- ควบคุมวาล์วได้สูงสุด 10 ชุด

General Features and Benefits: 

ควบคุมการปิด - เปิด ของวาล์วระบบกรองฝุ่น (Dust Filter)

ตั้งเวลาการเปิดและปิดได้

ควบคุมวาล์วได้สูงสุด 10 ชุด

            Jet Pulser JP99 This device controls the opening and closing of air valves in a reverse-pulse dust collector system. It allows for programmable timing and can control up to 10 valve units.

  • ON Timer Button Set a timeframe for Valve to complete the work. (90 to 200 msec)
  • OFF Timer Button Set a duration for Valve to stop operating. (1 to 120 sec)
  • Select Blow Down Cycles Button Set the number of operation cycles. (1 - 9 rounds)
  • Select Valves Number Button Determine the number of valves required. (1 - 10 Channels)

            For example, Valve 1 operates for 200 ms and then pauses for 30 seconds. Subsequently, Valve 2 operates according to the "ON/OFF Timer" settings, continuing through the sequence of valves specified by the "Select Valves Number" setting before cycling back to Valve 1. This operation repeats continuously until a trigger signal is received at the Stop input (Short Circuit). Upon receiving this signal, the valves operate according to the "ON/OFF Timer" settings but only for the number of cycles specified by the "Select Blow Down Cycles" setting; operation then halts until the trigger signal is removed from the Stop input, at which point the machine resumes operation.

Example of connecting the Jet Pulser JP99 with the Differential Pressure Transmitter DT20.

            The DT20 monitors the pressure level within the dust filter system. When the filter begins to clog and the pressure exceeds the setpoint, the DP95 sends a signal to the Jet Pulser (JP99) to blast dust off the filter bags; the JP99 ceases operation once the pressure returns to a normal level.

Warranty: 
5 years
Specifications

Input

Number of channel:

1 Channel

Input type:

Voltage

Input range:

220 VAC

Output

Number of channel:

10 Channels

Output type:

Triac (3A)

Indicators:

LED Display

Blowdown Cycles:

Programmable 1 to 9

No. of stations:

1 to 10 stations

Valve "ON" time:

90 to 200 msec

Valve "OFF" time:

1 to 120 sec

Power Requirements

Power Supply:

220 VAC

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W200 x H150 x D100 mm.

Mounting:

Wall mount

Protection:

IP65

Warranty

Warranty Period:

5 Year

Ordering
Ordering Information:  
Example JP99
Packagelist

Package Checklist

1. JP99

Downloads
Group Order
Product Order: 
4

JP16: Jet Pulser

- Control Valve (ON / OFF)

- 16 Channels Valve Input

General Features and Benefits: 

ควบคุมการ ปิด / เปิด ของวาล์วระบบกรองฝุ่น (Dust Filter)

ตั้งเวลาการเปิดและปิดได้

ควบคุมวาล์วได้สูงสุด 16 ชุด

            Jet Pulser JP16 This device controls the opening and closing of air valves for the Reverse Pulse Dust Collector system. It allows for programmable timing and can control up to 16 valve units.

  •  ON Timer button Set the valve operation time (90 to 200 ms).
  •  OFF Timer button Set the duration for the valve to stop operating (1 to 120 sec).
  •  Select Blow Down Cycles button Set the number of operating cycles (1 - 9 cycles).
  •  Select Valves Number button Specify the number of valves required (1-16 channels).

            For example, Valve 1 operates for 200 ms and then pauses for 30 seconds. Subsequently, Valve 2 operates according to the “ON/OFF Timer” settings, continuing the sequence through the number of valves specified in the “Select Valves Number” setting before cycling back to Valve 1. This operation repeats continuously until a trigger signal is received at the Stop input (Short Circuit). Upon receiving this signal, the valves operate according to the “ON/OFF Timer” settings but only for the number of cycles specified in “Select Blow Down Cycles,” after which they stop; operation resumes only after the trigger signal is removed from the Stop input.

The JP16 connection is compatible with the DP95 and DT20.

The JP16 connection is compatible with the DP31.

Connection example, Jet Pulser JP16 combined with Differential Pressure Controller DP31

            The DP31 monitors the pressure level within the dust filter system. When the filter begins to clog and the pressure exceeds the set value, the DP31 signals the JP16 Jet Pulser to blow dust off the filter bags; once the pressure drops back to a normal level, the JP16 stops operating.

Warranty: 
5 years
Specifications

Input

Number of channel:

1 Channel

Input type:

Solenoid Voltage

Input range:

110, 220 VAC

Output

Number of channel:

16 Channels

Output type:

Tiac (3A)

Indicators:

LED Display

Blowdown Cycles:

Programmable 1 to 9

No. of stations:

Programmable 1 to 16 stations

Valve "on" time:

90 to 200 msec

Valve "off" time:

1 to 120 sec

Power Requirements

Power Supply:

220 VAC

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W300 x H200 x D100 mm.

Mounting:

Wall mount

Protection:

IP65

Warranty

Warranty Period:

5 Year

Ordering
Ordering Information:  
Example JP16
Packagelist

Package Checklist

1. JP16

Downloads
Group Order
Product Order: 
3

SV95: Servo Controller


- Control Motorized Valves


- Controls Valve Opening From 0% To 100%


- 4-20 Ma Or 0-10 VDC Control Signal


- Relay Contact Output
General Features and Benefits: 

ควบคุมวาล์วแบบมอเตอร์

ควบคุมการเปิดวาล์ว 0 - 100%

สัญญาณควบคุม 4-20 mA หรือ 0-10 VDC

Relay Contact Output

           Server Controller SV95 This device controls the opening and closing position of a motorized valve, ensuring the valve's opening percentage corresponds to the received control signal. The Servo Controller SV95 accepts control signals-such as 4-20 mA or 0-10 VDC and outputs relay contact signals to command the motorized valve to rotate to the position dictated by the input signal.

            For example, within the 0-10 VDC control signal range, if the SV95 receives a 5 VDC signal, it will control the valve to open to the 50% position.

            Installation Recommendations

  1. If the valve position cannot be controlled after applying the input signal-causing the valve to rotate to the fully open or fully closed position the feedback potentiometer connections are incorrect; swap the wires connected to terminals 4 and 5.
     
  2. The Zero button is used to adjust the valve to the 0% position when the input signal is 0%.
     
  3. The Span button is used to adjust the valve to the 100% position when the input signal is 100%
     
  4. The Dead Band knob is used to adjust the system's sensitivity. If the motor oscillates continuously, increase the Dead Band setting by turning the knob clockwise until the oscillation stops.

Warranty: 
5 years
Specifications

Analog Input

Number of channel:

1 Channel

Input type:

Current, Voltage

Input range:

Current (4 to 20 mA)

Voltage (0 to 10 VDC (Optional))

Feedback Resistance:

100 Ω to 10 KΩ

Relay Output

Number of channel:

1 Channel

Relay Type:

N.O., N.C. (SPDT)

Contact Rating:

3 A @ 250 VAC

Dead Band:

1 to 10 % of input range

Span:

70 to 100 %

Zero:

0 to 20 %

Power Requirements

Power Supply:

110, 220 VAC

24 VDC (Optional)

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W50 x H70 x D130 mm.

Mounting:

Wall or DIN rail

Connection:

Plug - in 11 pins socket

Warranty

Warranty Period:

5 Year

Ordering
Ordering Information: Specify Input, Power Supply
Example SV95/4-20 mA/220 VAC
Packagelist

Package Checklist

1. SV95

Downloads
Group Order
Product Order: 
1

SR95: Zero Speed Relay

- ตรวจจับการหมุนของมอเตอร์

- ตรวจจับการทำงานของสายพาน

- ใช้กับ Proximity Switch ได้ทุกชนิด

 

General Features and Benefits: 

ตรวจจับการหมุนของมอเตอร์

ตรวจจับการทำงานของสายพาน

ใช้กับ Proximity Switch ได้ทุกชนิด

            Zero Speed Relay SR95 receives input pulse from proximity sensor. If the ppulse come continuously the relay will deenergize (OFF). But if the pulse miss within the preset time(“DELAY”) the relay will energize(ON). SR95 is used to detect under speed of gear motor, conveyor or slow moving object on the production line.

Warranty: 
5 years
Specifications

Digital Input

Number of channel:

1 Channel

Sensor Type:

DC Proximity Switch

2 Wire (NAMUR)

3 Wire (NPN or PNP)

Start - Delay:

0 to 30 Sec

Delay:

1 to 10 Sec

Frequency:

Max. 10 KHz

Relay Output

Number of channel:

1 Channel

Relay Type:

N.O., N.C. (SPDT)

Contact Rating:

3 A @ 250 VAC

Power Requirements

Power Supply:

110, 220 VAC

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W50 x H70 x D130 mm.

Mounting:

Wall or DIN Rail

Connection:

Plug - in 11 pins socket

Wiring:

Screw Terminals On Base Socket

Warranty

Warranty Period:

5 Year

Ordering
Ordering Information: Specify Power Supply
Example SR95/220VAC
Packagelist

Package Checklist

1. SR95

Downloads
Group Order
Product Order: 
2

HB20: Heater Break Relay

- Current Input (0-5 A, 0-10 A)

- Operating Mode Under or Over

General Features and Benefits: 

Current Input (0-5 A, 0-10 A)

Operating Mode Under or Over

Warranty: 
1 year
Specifications

Input

Number of channel:

1 Channel

Input type:

Current (AC)

Input range:

0 to 5, 0 to 10 A

Current Setpoint:

0 to 100 % of input range

Operating Mode:

Relay energized when Under Current

Relay Output

Number of channel:

1 Channel

Relay Type:

N.O. (SPDT)

Contact Rating:

5 A @ 250 VAC

Power Requirements

Power Supply:

220 VAC

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W65 x H65 x D32mm.

Warranty

Warranty Period:

1 Year

Ordering
Ordering Information: Specify Input
Example HB20/0-5 A
Packagelist

Package Checklist

1. HB20

Downloads
Datasheet: 
Group Order
Product Order: 
5

JP99: Jet Pulser

- ควบคุมการปิด - เปิด ของวาล์ว

- ตั้งเวลาการเปิดและปิดได้

- ควบคุมวาล์วได้สูงสุด 10 ชุด

General Features and Benefits: 

ควบคุมการปิด - เปิด ของวาล์วระบบกรองฝุ่น (Dust Filter)

ตั้งเวลาการเปิดและปิดได้

ควบคุมวาล์วได้สูงสุด 10 ชุด

            Jet Pulser JP99 เป็นอุปกรณ์ ควบคุมการปิด - เปิด วาล์วลม ของระบบทำความสะอาดถุงกำจัดฝุ่น (Reverse Pulse Dust Collector) สามารถตั้งเวลาการเปิดและปิดได้ ควบคุมวาล์วได้ สูงสุด 10 ชุด

  •  ปุ่ม ON Timer กำหนดระยะเวลาให้ Valve ทำงาน (90 to 200 msec)
  • ปุ่ม OFF Timer กำหนดระยะเวลาให้ Valve หยุดทำงาน (1 to 120 sec)
  • ปุ่ม Select Blow Down Cycles กำหนดจำนวนรอบการทำงาน (1 - 9 รอบ)
  • ปุ่ม Select Valves Number กำหนดจำนวน Valve ที่ต้องการใช้งาน (1 - 10 ช่อง)

            ตัวอย่างเช่น Valve 1 ทำงานเป็นเวลา 200 msec และหยุดทำงานเป็นเวลา 30 sec จากนั้น Valve 2 ถึงจะทำงานต่อไปตามระยะเวลาของ “ON/OFF Timer” จนถึงจำนวน Valve ที่กำหนดไว้จาก Select Valves Number และจะวนกลับมา Valve 1 อีกครั้ง ซึ่งการทำงานจะเป็นลักษณะแบบนี้ไปเรื่อยๆจนกว่าจะมีสัญญาณ Trig เข้ามาที่ช่อง Stop (Short Circuit) จะทำให้ Valve ทำงานตามระยะเวลาของ “ON/OFF Timer” แต่จะทำตามจำนวนรอบที่กำหนดไว้จาก Select Blow Down Cycles เท่านั้นแล้วจะหยุด จนกว่าสัญญาณ Trig จะหายไปจากช่อง Stop เครื่องถึงจะเริ่มทำงานต่อ

ตัวอย่างการต่อ Jet Pulser JP99 ร่วมกับ Differential Pressure Transmitter DT20
            โดย DT20 จะตรวจระดับ Pressure ในระบบ Dust Filter เมื่อ Filter เริ่มตันระดับ Pressure จะสูงกว่าค่าที่ตั้งไว้ DP95 จะส่งสัญญาณให้ Jet Pulser JP99 ทำงานเป่าฝุ่นออกจากถุงดักฝุ่นจนกระทั่งระดับPressure ลดลงในระดับปกติ JP99 จึงหยุดทำงาน

Warranty: 
5 years
Specifications

Input

Number of channel:

1 Channel

Input type:

Voltage

Input range:

220 VAC

Output

Number of channel:

10 Channels

Output type:

Triac (3A)

Indicators:

LED Display

Blowdown Cycles:

Programmable 1 to 9

No. of stations:

1 to 10 stations

Valve "ON" time:

90 to 200 msec

Valve "OFF" time:

1 to 120 sec

Power Requirements

Power Supply:

220 VAC

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W200 x H150 x D100 mm.

Mounting:

Wall mount

Protection:

IP65

Warranty

Warranty Period:

5 Year

Ordering
Ordering Information:  
Example JP99
Packagelist

Package Checklist

1. JP99

Downloads
Datasheet: 
Group Order
Product Order: 
4

JP16: Jet Pulser

- Control Valve (ON / OFF)

- 16 Channels Valve Input

General Features and Benefits: 

ควบคุมการ ปิด / เปิด ของวาล์วระบบกรองฝุ่น (Dust Filter)

ตั้งเวลาการเปิดและปิดได้

ควบคุมวาล์วได้สูงสุด 16 ชุด

            Jet Pulser JP16 เป็นอุปกรณ์ควบคุมการ ปิด - เปิด วาล์วลมของระบบทำความสะอาดถุงกำจัดฝุ่น (Reverse Pulse Dust Collector) สามารถตั้งเวลาการเปิดและปิดได้ ควบคุมวาล์วได้สูงสุด 16 ชุด

  •  ปุ่ม ON Timer กำหนดระยะเวลาให้ Valve ทำงาน (90 to 200 msec)
  •  ปุ่ม OFF Timer กำหนดระยะเวลาให้ Valve หยุดทำงาน (1 to 120 sec)
  •  ปุ่ม Select Blow Down Cycles กำหนดจำนวนรอบการทำงาน (1 - 9 รอบ)
  •  ปุ่ม Select Valves Number กำหนดจำนวน Valve ที่ต้องการใช้งาน (1 - 16 ช่อง)

ตัวอย่างเช่น Valve 1 ทำงานเป็นเวลา 200 msec และหยุดทำงานเป็นเวลา 30 sec จากนั้น Valve 2 ถึงจะทำงานต่อไปตามระยะเวลาของ “ON/OFF Timer” จนถึงจำนวน Valve ที่กำหนดไว้จาก Select Valves Number และจะวนกลับมา Valve 1 อีกครั้ง ซึ่งการทำงานจะเป็นลักษณะแบบนี้ไปเรื่อยๆจนกว่าจะมีสัญญาณ Trig เข้ามาที่ช่อง Stop (Short Circuit) จะทำให้ Valve ทำงานตามระยะเวลาของ “ON/OFF Timer” แต่จะทำตามจำนวนรอบที่กำหนดไว้จาก Select Blow Down Cycles เท่านั้นแล้วจะหยุด จนกว่าสัญญาณ Trig จะหายไปจากช่อง Stop แล้วจึงจะเริ่มทำงานต่อ

การเชื่อมต่อ JP16 ใช้งานร่วมกับ DP95 และ DT20

การเชื่อมต่อ JP16 ใช้งานร่วมกับ DP31

ตัวอย่างการต่อใช้งาน      Jet Pulser JP16 ร่วมกับ Differential Pressure Controller DP31
            โดย DP31 จะตรวจระดับ Pressure ในระบบ Dust Filter เมื่อ Filter เริ่มตัน ระดับ Pressure จะสูงกว่าค่าที่ตั้งไว้ DP31 จะส่งสัญญาณให้ Jet Pulser JP16 ทำงานเป่าฝุ่นออกจากถุงดักฝุ่นจนกระทั่งระดับ Pressure ลดลงในระดับปกติ JP16 จึงหยุดทำงาน

Warranty: 
5 years
Specifications

Input

Number of channel:

1 Channel

Input type:

Solenoid Voltage

Input range:

110, 220 VAC

Output

Number of channel:

16 Channels

Output type:

Tiac (3A)

Indicators:

LED Display

Blowdown Cycles:

Programmable 1 to 9

No. of stations:

Programmable 1 to 16 stations

Valve "on" time:

90 to 200 msec

Valve "off" time:

1 to 120 sec

Power Requirements

Power Supply:

220 VAC

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W300 x H200 x D100 mm.

Mounting:

Wall mount

Protection:

IP65

Warranty

Warranty Period:

5 Year

Ordering
Ordering Information:  
Example JP16
Packagelist

Package Checklist

1. JP16

Downloads
Datasheet: 
Group Order
Product Order: 
3

SR95: Zero Speed Relay

- ตรวจจับการหมุนของมอเตอร์

- ตรวจจับการทำงานของสายพาน

- ใช้กับ Proximity Switch ได้ทุกชนิด

 

General Features and Benefits: 

ตรวจจับการหมุนของมอเตอร์

ตรวจจับการทำงานของสายพาน

ใช้กับ Proximity Switch ได้ทุกชนิด

            Zero Speed Relay SR95 เป็นอุปกรณ์ที่รับสัญญาณ Pulse จาก Proximity Sensor ถ้าสัญญาณ Pulse มาอย่างต่อเนื่อง Relay ของ SR95 จะ “OFF” แต่ถ้าสัญญาณ Pulse ขาดหายไปนานกว่าช่วงเวลาที่ตั้งไว้ Relay SR95 จะ “ON” Zero Speed Relay SR95 มีประโยชน์ในการตรวจจับว่า Motor หยุดหมุน, ความเร็วลดลง, สานพานขาดหรือชิ้นงานในสายการผลิตขาดหายไป ปุ่มปรับค่าของ SR95 มีหน้าที่ ดังต่อไปนี้

  • Start Delay ปรับค่าหน่วงเวลาเมื่อเริ่ม Start ระบบไม่ให้ Relay ทำงานปรับได้ 0-30 วินาที (เวลาเริ่ม Start นับจากเมื่อเริ่มจ่าย Supply ให้ SR95
     
  • Delay ตั้งหน่วยเวลาที่สัญญาณ Pulse ขาดหายไปถ้า Pulse ไม่มาต่อเนื่องภายในช่วงเวลา Delay ที่ตั้งไว้ Relay จะ “ON”
     
  • Reset เป็นปุ่มกด Reset ให้ Relay “OFF” ให้ Mode Manual Reset

Warranty: 
5 years
Specifications

Digital Input

Number of channel:

1 Channel

Sensor Type:

DC Proximity Switch

2 Wire (NAMUR)

3 Wire (NPN or PNP)

Start - Delay:

0 to 30 Sec

Delay:

1 to 10 Sec

Frequency:

Max. 10 KHz

Relay Output

Number of channel:

1 Channel

Relay Type:

N.O., N.C. (SPDT)

Contact Rating:

3 A @ 250 VAC

Power Requirements

Power Supply:

110, 220 VAC

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W50 x H70 x D130 mm.

Mounting:

Wall or DIN Rail

Connection:

Plug - in 11 pins socket

Wiring:

Screw Terminals On Base Socket

Warranty

Warranty Period:

5 Year

Ordering
Ordering Information: Specify Power Supply
Example SR95/220VAC
Packagelist

Package Checklist

1. SR95

Downloads
Datasheet: 
Group Order
Product Order: 
2

SV95: Servo Controller

- ควบคุมวาล์วแบบมอเตอร์

- ควบคุมการเปิดวาล์ว 0 - 100%

- สัญญาณควบคุม 4-20 mA หรือ 0-10 VDC

- Relay Contact Output

General Features and Benefits: 

ควบคุมวาล์วแบบมอเตอร์

ควบคุมการเปิดวาล์ว 0 - 100%

สัญญาณควบคุม 4-20 mA หรือ 0-10 VDC

Relay Contact Output

           Server Controller SV95 เป็นอุปกรณ์ที่ใช้ควบคุมตำแหน่งการ เปิด-ปิด ของวาล์วแบบมอเตอร์เพื่อให้เปอร์เซ็นต์ การเปิดของวาล์วสัมพันธ์กับสัญญาณควบคุมที่ส่งมา โดย Servo Controller SV95 รับสัญญาณควบคุม เช่น 4-20 mA, 010 VDC SV95 จะส่งสัญญาณเป็น Relay Contact ไปสั่งให้วาล์วแบบมอเตอร์หมุนไปยังตำแหน่งตามเปอร์เซ็นต์ของสัญญาณควบคุมที่ได้รับ

            ตัวอย่างเช่น ใน Range สัญญาณควบคุม 0 -10 VDC ถ้า SV95 ได้รับสัญญาณ 5VDC  SV95 จะควบคุมให้วาล์วเปิดที่ตำแหน่ง 50% เป็นต้น

            ข้อแนะนำในการติดตั้ง

  1. ถ้าป้อนสัญญาณ Input แล้วไม่สามารถควบคุมตำแหน่งของวาล์วได้ โดยวาล์วหมุนไปตำแหน่ง เปิดหรือปิดสุดด้านใดด้านหนึ่ง แสดงว่าขั้ว Feedback Pot. ไม่ถูกต้องให้สลับสายระหว่างขั้ว 4 และ 5
     
  2. ปุ่ม Zero ใช้ปรับให้วาล์วอยู่ที่ตำแหน่ง 0% เมื่อสัญญาณ Input 0%
     
  3. ปุ่ม Span ใช้ปรับให้วาล์วอยู่ที่ตำแหน่ง 100% เมื่อสัญญาณ Input 100%
     
  4. ปุ่ม Dead Band ใช้ปรับ Sensitivity ของระบบ ถ้ามอเตอร์มีอาการหมุนไปมาตลอดเวลา (Oscillate) ให้ปรับเพิ่ม Dead Band โดยหมุนปุ่ม Dead Band ตามเข็มนาฬิกา จนมอเตอร์หยุด Oscillate

Warranty: 
5 years
Specifications

Analog Input

Number of channel:

1 Channel

Input type:

Current, Voltage

Input range:

Current (4 to 20 mA)

Voltage (0 to 10 VDC (Optional))

Feedback Resistance:

100 Ω to 10 KΩ

Relay Output

Number of channel:

1 Channel

Relay Type:

N.O., N.C. (SPDT)

Contact Rating:

3 A @ 250 VAC

Dead Band:

1 to 10 % of input range

Span:

70 to 100 %

Zero:

0 to 20 %

Power Requirements

Power Supply:

110, 220 VAC

24 VDC (Optional)

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W50 x H70 x D130 mm.

Mounting:

Wall or DIN rail

Connection:

Plug - in 11 pins socket

Warranty

Warranty Period:

5 Year

Ordering
Ordering Information: Specify Input, Power Supply
Example SV95/4-20 mA/220 VAC
Packagelist

Package Checklist

1. SV95

Downloads
Datasheet: 
Group Order
Product Order: 
1