- HOME
- PRODUCTS
- 2-Wire Transmitter
- 4-Wire Transmitter
- 4-Wire Transmitter (2 Outputs)
- Power Transducer
- Digital Panelmeter
- Big Digital Display (100 mm. Height)
- A.C. Panel Meter
- Data Logger
- Data Acquisition, MODBUS I/O Module (RS-232, RS-485)
- Data Communications
- Wireless Module
- 2-Wire Remote
- Touch Screen
- Calibrator
- Power Protective Relay
- Alarm Module
- Control Module
- PLC Analog Input-Output
- Accessories
- APPLICATIONS
- SUPPORTS
- CONTACT US
PLC Analog Input-Output
PF96: Potentiometer To Frequency
![]() |
- Interface to PLC digital input
- Sense position of potentiometer - Linearized output - Isolation between input, Output and power supply |
General Features and Benefits:
Interface to PLC digital input
Sense position of potentiometer
Linearized output
Isolation between input, Output and power supply
Potentiometer To Frequency PF96 This device enables a PLC to read the position of a potentiometer. The PF96 operates by converting the potentiometer's position into a frequency signal fed into the PLC's digital input; the PLC's high-speed counter then measures this signal's frequency, which varies in proportion to the potentiometer's position. The PF96 is useful for applications such as remote setpoint control or machinery position monitoring for instance, indicating the degree to which a damper is open and can also be adapted for liquid level measurement.

Warranty:
5 years
DF96: DC To Frequency
![]() |
- Interface to PLC digital input
- Programmable Range - Linearized output - Isolated input to output to Power supply - D.C. input voltage or current |
General Features and Benefits:
Interface to PLC digital input
Programmable Range
Linearized output
Isolated input to output to Power supply
D.C. input voltage or current
DC To Frequency DF96 This device enables a PLC to accept DC current or DC voltage signals without requiring an analog input channel. The DF96 operates by converting the DC signal into a frequency signal fed to the PLC's digital input; the PLC's high-speed counter then measures this frequency, which varies in proportion to the DC input value. This device allows Micro PLCs which typically only accept digital inputs to process DC current or DC voltage signals.

Warranty:
5 years
RF96: RTD To Frequency
![]() |
- Interface to PLC digital input
- Programmable Range - Isolated input to output to Power supply - True lead length compensation |
General Features and Benefits:
Interface to PLC digital input
Programmable Range
Isolated input to output to Power supply
True lead length compensation
RTD To Frequency RF96 This device enables a PLC to acquire temperature readings from a PT100 sensor without requiring an analog input channel. The RF96 operates by converting temperature values into a frequency signal fed to the PLC's digital input; the PLC's high-speed counter then measures this signal frequency, which varies in proportion to the temperature. This device is particularly useful for Micro PLCs which typically only accept digital inputs allowing them to receive temperature data from PT100 sensors.

Warranty:
5 years
TF96: Thermocouple To Frequency
![]() |
- Interface to PLC digital input
- Programmable range - Linearized output - Isolation of input, output and power supply - Cold junction compensation |
General Features and Benefits:
Interface to PLC digital input
Programmable range
Linearized output
Isolation of input, output and power supply
Cold junction compensation
Thermocouple To Frequency TF96 This device enables a PLC to receive temperature readings from a thermocouple sensor without requiring an analog input channel. It converts temperature values into a frequency signal fed to the PLC's digital input; the PLC's high-speed counter then measures the signal frequency, which varies in proportion to the temperature. The TF96 is particularly useful for allowing Micro PLCs which typically only accept digital input signals to receive temperature data from thermocouples.

Warranty:
5 years
DA98: D To A Converter
![]() |
- 8 bit D to A converter
- Isolated input, output - PLC analog Output |
General Features and Benefits:
8 bit D to A converter
Isolated input, output
PLC analog Output
D To A Converter DA 98 received digital signal from Digital Output of PLC inform of Binary Code, and then transmitting to Analog (0 to 10 VDC, 4 to 20 mA, 1 to 5 VDC) DA98 is help to control analog signal using Digital output signal of PLC.

Warranty:
5 years
DA98: D To A Converter
![]() |
- 8 bit D to A converter
- Isolated input, output - PLC analog Output |
General Features and Benefits:
8 bit D to A converter
Isolated input, output
PLC analog Output
D To A Converter DA 98 จะรับสัญญาณ Digital จาก Digital Output ของ PLC ในรูปของ Binary Code แปลงเป็นค่า Analog (0 to 10 VDC, 4 to 20 mA, 1 to 5 VDC) อุปกรณ์ DA98 ช่วยให้สามารถใช้ Digital Output ของ PCL ควบคุมสัญญาณ Analog ได้ โดยไม่จำเป็นต้องใช้ Analog Output ของ PLC

Warranty:
5 years
PF96: Potentiometer To Frequency
![]() |
- Interface to PLC digital input
- Sense position of potentiometer - Linearized output - Isolation between input, Output and power supply |
General Features and Benefits:
Interface to PLC digital input
Sense position of potentiometer
Linearized output
Isolation between input, Output and power supply
Potentiometer To Frequency PF96 เป็นอุปกรณ์ที่ช่วยให้ PLC สามารถรับค่าตำแหน่งของ Potentiometer ได้ โดย PF96 ใช้หลักการเปลี่ยนค่าตำแหน่งของ Potentiometer เป็นสัญญาณความถี่ป้อนให้ PLC ทาง Digital Input ของ PLC แล้วใช้ High Speed Counter ของ PLC วัดความถี่ของสัญญาณ ซึ่งค่าความถี่ที่ได้จะแปรผันตามตำแหน่งของ Potentiometer PF96 นี้มีประโยชน์ ในการใช้ทำ Remote Setpoint หรือบอกตำแหน่งของเครื่องจักร เช่น บอกตำแหน่งของ Damper ว่า เปิดมากหรือน้อย หรือไปดัดแปลงใช้ในการวัดระดับของของเหลว

Warranty:
5 years
DF96: DC To Frequency
![]() |
- Interface to PLC digital input
- Programmable Range - Linearized output - Isolated input to output to Power supply - D.C. input voltage or current |
General Features and Benefits:
Interface to PLC digital input
Programmable Range
Linearized output
Isolated input to output to Power supply
D.C. input voltage or current
DC To Frequency DF96 เป็นอุปกรณ์ที่ช่วยให้ PLC สามารถรับค่าสัญญาณ D.C. Current หรือ D.C. Voltage ได้ โดยไม่ต้องใช้ Analog Input Channel โดย DF96 ใช้หลักการเปลี่ยนค่า D.C. เป็นสัญญาณความถี่ป้อนให้ PLC ทาง Digital Input ของ PLC แล้วใช้ High Speed Counter ของ PLC วัดความถี่ของสัญญาณ ซึ่งค่าความถี่ที่ได้จะแปรผันตามค่า D.C. DF96 นี้มีประโยชน์ช่วยให้ Micro PLC ปกติรับได้แต่สัญญาณ Digital Input สามารถรับสัญญาณ D.C. Current หรือ D.C. Voltage ได้

Warranty:
5 years
RF96: RTD To Frequency
![]() |
- Interface to PLC digital input
- Programmable Range - Isolated input to output to Power supply - True lead length compensation |
General Features and Benefits:
Interface to PLC digital input
Programmable Range
Isolated input to output to Power supply
True lead length compensation
RTD To Frequency RF96 เป็นอุปกรณ์ที่ช่วยให้ PLC สามารถรับค่าอุณหภูมิจาก PT100 Sensor ได้โดยไม่ต้องใช้ Analog Input Channel โดย RF96 ใช้หลักการเปลี่ยนค่าอุณหภูมิเป็นสัญญาณความถี่ป้อนให้ PLC ทาง Digital Input ของ PLC แล้วใช้ High Speed Counter ของ PLC วัดความถี่ของสัญญาณ ซึ่งค่าความถี่ที่ได้จะแปรผันตามอุณหภูมิ RF96 นี้มีประโยชน์ ช่วยให้ Micro PLC ซึ่งปรกติรับได้แต่สัญญาณ Digital Input สามารถ รับสัญญาณอุณหภูมิจาก PT100 ได้

Warranty:
5 years
TF96: Thermocouple To Frequency
![]() |
- Interface to PLC digital input
- Programmable range - Linearized output - Isolation of input, output and power supply - Cold junction compensation |
General Features and Benefits:
Interface to PLC digital input
Programmable range
Linearized output
Isolation of input, output and power supply
Cold junction compensation
Thermocouple To Frequency TF96 เป็นอุปกรณ์ที่ช่วยให้ PLC สามารถรับค่าอุณหภูมิจาก Thermocouple Sensor ได้ โดยไม่ต้องใช้ Analog Input Channel การเปลี่ยนค่าอุณหภูมิเป็นสัญญาณความถี่ป้อนให้ PLC ทาง Digital Input ของ PLC แล้วใช้ High Speed Counter ของ PLC วัดความถี่ของสัญญาณ ซึ่งค่าความถี่ที่ได้จะแปรผันตามอุณหภูมิ TF96 นี้มีประโยชน์ ช่วยให้ Micro PLC ซึ่งปรกติรับได้แต่สัญญาณ Digital Input สามารถรับสัญญาณอุณหภูมิจาก Thermocouple ได้

Warranty:
5 years