2-Wire Transmitter

CS295: Current Loop Supply

- Power supply for 2 wire transmitter

- Supplies 2 Current Loops

- Isolation between each Current Loop

  and power supply

- Current limiting (short circuit protected)

General Features and Benefits: 

Power supply for 2 wire transmitter

Supplies 2 Current Loops

Isolation between each Current Loop and power supply

Current limiting (short circuit protected)

            The Current Loop Supply CS295 supplies power to 2-wire transmitters and generates output signal 4-20 mA. or 1-5 v. Isolation between each Current Loops and power supply is provided. Current limiting (to protect against transmitter wiring short circuits) is also provided. The electronic components are fitted on circuit boards enclosed in a plastic housing suitable for mounting on a standard rail 35 mm.

Warranty: 
5 years
Specifications

Analog Output

Number of Channel:

2 Channels

Output type:

Voltage

Output range:

24 VDC (Regulated)

4 to 20 mA, 1 to 5 VDC(Output Signal)

Output Impedance:

Max. 250 Ω

Current Limitation:

36 mA.

Isolation voltage:

Between Each Current Loops and power supply

Short Circuit Duration:

No Limit

Dielectric Strength:

500 VAC for 1 minute

Power Requirements

Power Supply:

100, 110, 220 VAC.

24, 110, 125 VDC Option

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

50 x H70 x D130 mm.

Mounting:

Wall or DIN rail

Construction:

plug - in

Wiring:

Screw terminals on base socket

Warranty

Warranty Period:

5 year

Ordering
Ordering Information: Specify Output, Power Supply
Example CS295/4-20 mA/220 VAC
Packagelist

Package Checklist

1. CS295

Downloads
Group Order
2 Wire Transmitter: 
11

CS198: Current Loop Supply (Isolated 2 Channels)

- Power 2 wire transmitter

- 2 Isolated Channels Output

- Output 4-20 mA, 1-5 V, 0-10 V

- Din rail mounting

General Features and Benefits: 

Power 2 Wire Transmitter

2 Channels Output 4-20 mA, 1-5 VDC, 0-10 VDC

Isolated between input, output and supply

            The Current Loop Supply CS198 provides a floating DC supply for energizing a 2-wire transmitter and repeats the transmitter signal in another two floating circuits to drive loads.

Warranty: 
5 years
Specifications

Analog Input

Number of channel:

1 Channel

Input type:

Current

Input range:

4 to 20 mA

Input impedance:

Max 20 Ω

Analog Output

Number of channel:

2 Channels (Isolated)

Output type:

Current, Voltage

Output range:

Voltage (1 to 5 VDC, 0 to 10 VDC)

Current (4 to 20 mA)

Linearity:

< ± 0.1% of span

Isolation voltage:

500 VAC, 1 min. between input, output, and power supply

Transmitter power supply:

36 mA @ 24 VDC

Power Requirements

Power Supply:

110, 220 VAC

24, 110, 125 VDC

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W50 x H70 x D130 mm.

Mounting:

Wall or DIN Rail

Construction:

Plug-In

Wiring:

Screw terminals on base socket

Warranty

Warranty Period:

5 year

Ordering
Ordering Information: Specify Output1, Output2, Power supply
Example CS198/4-20 mA/1-5 VDC/220 VAC
Packagelist

Package Checklist

1. CS198

Downloads
Group Order
2 Wire Transmitter: 
13

CS195: Current Loop Supply (Isolate)

- Powers 2 wire transmitter

- Intrinsically saft without barriers or safety

  earth

- Output 4-20mA, 1-5V, 0-10V

- DIN rail mounting

General Features and Benefits: 

Power 2 Wire Transmitter

Output 4-20 mA, 1-5 VDC, 0-10 VDC

Isolated between input, output and supply

            The Current Loop Supply CS195 provides a floting DC supply for energizing a 2-wire transmitter in a hazardous area,and repeats the transmitter signal in another floating circuit to drive a safe-area load. The unit is intrinsically saft for connection to Zone 0,1 or 2 hazardous-area wiring, dose not require the use of safty barriers and dispenses with the need for isolation in transmitters used with earthed or poorly insulated sensors.

Warranty: 
5 years
Specifications

Analog Input

Number of channel:

1 Channel

Input type:

Current

Input range:

4 to 20 mA

Input impedance:

Max 20 Ω

Analog Output

Number of Channel:

1 Channel

Output type:

Current, Voltage

Output range:

Voltage (1 to 5 VDC, 0 to 10 VDC)

Current (4 to 20 mA)

Linearity:

< ± 0.2 % of span

Isolation voltage:

500 VAC, 1 min. between input, output, and power supply

Transmitter power supply:

36 mA @ 24 VDC

Power Requirements

Power Supply:

110, 220 VAC

24, 110, 125 VDC Option

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W 50 x H70 x D130 mm

Mounting:

Wall or DIN rail

Construction:

plug - in

Wiring:

Screw terminals on base socket

Warranty

Warranty Period:

5 year

Ordering
Ordering Information: Specify Output, Power supply
Example CS195/4-20 mA/220 VAC
Packagelist

Package Checklist

1. CS195

Downloads
Group Order
2 Wire Transmitter: 
12

HR370: Humidity Transmitter

- Precision Relative Humidity ± 3 % RH

- Humidity Range 0 - 100 % RH

- Output 2 Wire 4 - 20 mA (Loop Powered)

General Features and Benefits: 

Precision Relative Humidity ± 3 % RH

Humidity Range 0 - 100 % RH

Output 2 Wire 4 - 20 mA (Loop Powered)

            The Humidity Transmitter HR370 อุปกรณ์วัดความชื้นสัมพัทธ์แล้วแปลงสัญญาณความชื้นสัมพัทธ์เป็นสัญญาณมาตรฐานทางไฟฟ้า 4 - 20 mA โดย HR370 ถูกออกแบบให้เหมาะกับการติดตั้งกับฝาพนัง สามารถติดตั่งในบริเวณที่มีฝุ่นหรือละอองน้ำได้

monitor or record data the humidity.

Warranty: 
1 year
Specifications

Input

Number of Channel:

1 Channel

Input Type:

Humidity

Input Range:

Input Range: 0 to 100 % RH

Working Range: 5 to 95 % RH

Response Time: 1 sec.

Precision Relative: ± 3 % RH (Max.), 0 - 80 % RH

Analog Output

Number of Channel:

1 Channel

Output Type:

Current (2-Wire)

Output Range:

4 to 20 mA

Loop Powered:

15 to 35 VDC

Output Load Resistance:

Rload (Max.) = (Vsupply - 15)/0.02

Isolation Voltage:

500 Vrms, Between Output

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W65 x H140 x D55 mm.

Protection:

IP67

Warranty

Warranty Period:

1 Year

Ordering
Ordering Information:  
Example HR370
Packagelist

Package Checklist

1. HR370

Downloads
Group Order
2 Wire Transmitter: 
1.1

CS20: Current Loop Supply

- Power Supply for 2-wire Transmitter

- Supplies 8 Current Loops

- Current Limiting

- Short Circuit Protected (Relay Alarm)


 
General Features and Benefits: 

Power Supply for 2-wire Transmitter

Supplies 8 Current Loops

Current Limiting

Short Circuit Protected (Relay Alarm)

            The Current Loop Supply CS20 supplies power to 2 - wire transmitters (8 Channels) and generates output signal 4 - 20 mA. Current limiting (to protect against transmitter wiring short circuits) is also provided.

Warranty: 
5 years
Specifications

Analog Input

Number of Channel:

8 Channels

Input Type:

Current (24 VDC Loop-Powered)

Input Range:

4 to 20 mA

Analog Output

Number of Channel:

8 Channels

Output Type:

Current

Output Range:

4 to 20 mA

Short Circuit Duration:

28 mA

Relay Output

Number of Channel:

1 Channel

Relay Type:

N.O.

Contact Rating:

3 A @ 250 VAC/24 VDC

Power Requirements

Power Supply:

24 VDC (500 mA OK.)

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W62 x H142 x D50 mm.

Mounting:

DIN Rail

Warranty

Warranty Period:

5 Year

Ordering
Ordering Information:  
Example CS20
Packagelist

Package Checklist

1. CS20

Downloads
Group Order
2 Wire Transmitter: 
13.1

CS20: Current Loop Supply

- Power Supply for 2-wire Transmitter

- Supplies 8 Current Loops

- Current Limiting

- Short Circuit Protected (Relay Alarm)


 
General Features and Benefits: 

Power Supply for 2-wire Transmitter

Supplies 8 Current Loops

Current Limiting

Short Circuit Protected (Relay Alarm)

            The Current Loop Supply CS20 อุปกรณ์ที่ใช้สำหรับจ่ายพลังงานให้เซ็นเซอร์ 4 - 20 mA, 2-Wire Transmitter (Loop Supply) สามารถรองรับได้ถึง 8 เซ็นเซอร์ และยังมีการจำกัดกระแสเพื่อปกป้องตัวเซ็นเซอร์ในกรณีที่เกิดการลัดวงจร

Warranty: 
5 years
Specifications

Analog Input

Number of Channel:

8 Channels

Input Type:

Current (24 VDC Loop-Powered)

Input Range:

4 to 20 mA

Analog Output

Number of Channel:

8 Channels

Output Type:

Current

Output Range:

4 to 20 mA

Short Circuit Duration:

28 mA

Relay Output

Number of Channel:

1 Channel

Relay Type:

N.O.

Contact Rating:

3 A @ 250 VAC/24 VDC

Power Requirements

Power Supply:

24 VDC (500 mA OK.)

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W62 x H142 x D50 mm.

Mounting:

DIN Rail

Warranty

Warranty Period:

5 Year

Ordering
Ordering Information:  
Example CS20
Packagelist

Package Checklist

1. CS20

Downloads
Datasheet: 
Group Order
2 Wire Transmitter: 
13.1

HT130: Humidity & Temperature Transmitter

- Working Range (-)40 to 125 °C

- Precision Relative Humidity ± 3 % RH

- High Accuracy Temperature ± 0.4 °C

- Output 2 Wire 4-20 mA (Loop Powered)

General Features and Benefits: 

Working Range (-)40 to 125 °C

Precision Relative Humidity ± 3 % RH

High Accuracy Temperature ± 0.4 °C

Output 2 Wire 4-20 mA (Loop Powered)

            The Humidity & Temperature Transmitter HT130 fit the requirement of accurate monitor the humidity and temperature in ambient air. The transmitter continuously measures the ambient humidity and provides an accurate, linear 4-20 mA output signal.

Warranty: 
1 year
Specifications

Input

Number of Channel:

2 Channels

Input Type:

Humidity, Temperature

Input Range:

Humidity

Input Range: 0 to 100 % RH

Working Range: 5 to 95 % RH

Response Time: 1 sec.

Precision Relative: ± 3 % RH (Max.), 0 - 80 % RH

Temperature

Input Range: (-)40 to 125 °C

Working Range: (-)40 to 125 °C (Probe)

Accuracy: ± 0.4 °C (Max.), (-)10 to 85 °C

Analog Output

Number of Channel:

2 Channels

Output Type:

Current (2 Wire)

Output Range:

4 to 20 mA

Loop Powered:

12 to 35 VDC

Output Load Resistance:

Rload (Max.) = (Vsupply - 15)/0.02

Isolation Voltage:

500 Vrms, Between Output

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W65 x H140 x D55 mm.

Probe/Cable Length:

215/800 mm.

Probe Diameter:

19 mm.

Warranty

Warranty Period:

1 Year

Ordering
Ordering Information:  
Example HT130
Packagelist

Package Checklist

1. HT130

Downloads
Group Order
2 Wire Transmitter: 
10

HT120: Humidity & Temperature Transmitter

- Precision Relative Humidity ± 3 % RH

- High Accuracy Temperature ± 0.4 °C

- Output 2 Wire 4-20 mA (Loop Powered)

General Features and Benefits: 

Precision Relative Humidity ± 3 % RH

High Accuracy Temperature ± 0.4 °C

Output 2 Wire 4-20 mA (Loop Powered)

            The Humidity & Temperature Transmitter HT120 fit the requirement of accurate monitor the humidity and temperature in ambient air. The transmitter continuously measures the ambient humidity and provides an accurate, linear 4-20 mA output signal.

Warranty: 
1 year
Specifications

Input

Number of Channel:

2 Channels

Input Type:

Humidity, Temperature

Input Range:

Humidity

Input Range: 0 to 100 % RH

Working Range: 5 to 95 % RH

Response Time: 1 sec.

Precision Relative: ± 3 % RH (Max.), 0 - 80 % RH

Temperature

Input Range: 0 to 100 °C

Working Range: 0 to 60 °C

Accuracy: ± 0.4 °C (Max.), (-)10 to 85 °C

Analog Output

Number of Channel:

2 Channels

Output Type:

Current (2-Wire)

Output Range:

4 to 20 mA

Loop Powered:

12 to 35 VDC

Output Load Resistance:

Rload (Max.) = (Vsupply - 15)/0.02

Isolation Voltage:

500 Vrms, Between Output

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W65 x H140 x D55 mm.

Protection:

IP67

Warranty

Warranty Period:

1 Year

Ordering
Ordering Information:  
Example HT120
Packagelist

Package Checklist

1. HT120

Downloads
Group Order
2 Wire Transmitter: 
9

TR37: Temperature Transmitter

- High Accuracy Temperature ± 0.4 °C

- Temperature Range 0 - 100 °C

- Output 2 Wire 4-20 mA (Loop Power)

General Features and Benefits: 

High Accuracy Temperature ± 0.4 °C

Temperature Range 0 - 100 °C

Output 2 Wire 4-20 mA (Loop Power)

            Temperature Transmitter TR37 is device that converts temperature to electrical signal (4 – 20 mA) and send to signal receiver such as PLC, Recorder, Controller, indicator etc.

Warranty: 
1 year
Specifications

USB Interface

Compliance:

USB 1.1/2.0

Connector:

USB Mini Type B

Speed:

12 Mbps (Full - Speed USB)

Class:

CDC

Temperature Input

Number of Channel:

1 Channel

Input Type:

Temperature

Input Range:

0 to 100 °C

Working Range:

0 to 60 °C

Response Time:

1 sec.

Accuracy:

± 0.4 °C (Max.), (-)10 to 85 °C

Analog Output

Number of Channel:

1 Channel

Output Type:

Current (2-Wire)

Output Range:

4 to 20 mA

Loop Powered:

12 to 35 VDC

Output Load Resistance:

Rload (Max.) = (Vsupply - 15)/0.02

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W75 x H125 x D50 mm.

Probe Length:

W80 mm.

Probe Diameter:

9.5 mm.

Warranty

Warranty Period:

1 Year

Ordering
Ordering Information:  
Example TR37
Packagelist

Package Checklist

1. TR37

Downloads
Group Order
2 Wire Transmitter: 
1

SI99: Signal Isolator

- Intrinsically safe isolation without
  power supply

- Eliminating ground-loop

- 2 channels available

- High accuracy and stability

General Features and Benefits: 

Intrinsically safe isolation without power supply

Eliminating ground-loop

2 channels available

High accuracy and stability

            The WISCO Signal Isolator SI99 is a WISCO Industries product designed to break the galvanic path between a transmitted signal source and a receiving device, such as a controller or recorder. The Signal Isolator solves the problem of transferred signal distortion due to ground potential differences. The Signal Isolator is highly effective in eliminating unreliable or inaccurate signal transfer by providing total current-to-current signal isolation. The Signal Isolator derives its operating potential from the existing input loop current and, therefore, does not require a dedicated power supply. The Signal Isolator is placed in series with the drive signal and provides and output current that is proportional to the input signal current.

            When a signal isolation device is installed it is important to consider the voltage drop or additional line resistance that will be placed in the system. Any additional load tends to reduce the line or drive potential and may exceed the source rating. The effect of voltage drop within the system must be calculated to ensure that drive capability is not exceeded. The Signal Isolator features a maximum fixed voltage drop of 2.5 VDC (4.2 V for 10 - 50 mA) which remains constant over the entire temperature range of 0 °C to 50 °C

            ลักษณะการใช้งานของ Signal Isolator

            1) ป้องกันการเกิด Ground Loops ซึ่งเป็นสาเหตุ ทำให้ค่าวัดไม่คงที่ หรือผิดจากความเป็นจริง

           2) ป้องกันความเสียหายที่จะเกิดขึ้นกับ PLC หรือ DCS เนื่องจากสัญญาณรบกวนที่เกิดขึ้นทางด้าน Transmitter เช่น ฟ้าผ่า หรือจาก A.C. Line โดยตัว Signal Isolator ทำหน้าที่เหมือนกำแพงที่ป้องกัน ไม่ให้สัญญาณเหล่านี้ ส่งเข้าไปทำความเสียหายให้ PLC หรือ DCS ได้

 

Warranty: 
5 years
Specifications

Analog Input

Number of channel:

2 Channels

Input type:

Current

Input range:

4 to 20 mA

10 to 50 mA

Input impedance:

130 + Load resistance (4 to 20 mA)

85 + Load resistance (10 to 50 mA)

Analog Output

Number of channel:

2 Channels (Isolated)

Output type:

Current

Output range:

4 to 20 mA, 10 to 50 mA.

Current Limitation:

Max 250 (2.5 VDC. at 20 mA)

Isolation voltage:

500 VAC.

Linearity:

Better then + 0.2% of span

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W 50 x H 70 x D 130 mm.

Mounting:

Wall or DIN rail

Construction:

Plug - in 11 pins socket

Warranty

Warranty Period:

5 year

Ordering
Ordering Information:  
Example SI99

 

Packagelist

Package Checklist

1. SI99

Downloads
Group Order
2 Wire Transmitter: 