Power Transducer
CT: Current Transformer
General Features and Benefits:
Rate Voltage: 660 VAC
Output Capacity: 5 VA Max.
Accuracy Class: 0.5
Warranty:
1 year
FQ95: Frequency Transducer
- Voltage Input 110 VAC, 220 VAC
- Analog Output 4-20 mA, 0-5 VDC, 0-10 VDC |
General Features and Benefits:
Voltage Input 110 VAC, 220 VAC
Analog Output 4-20 mA, 0-5 VDC, 0-10 VDC
Frequency Transducer FQ95 provided a precision DC output proportional to deviation from center frequency (50 or 60Hz) of AC. supply.
Warranty:
5 years
VAR95: Var Transducer
- Voltage Input 110 VAC, 220 VAC, 380 VAC
- Current Input 1 A, 5 A - Analog Output 4-20 mA, 0-5 VDC |
General Features and Benefits:
Voltage Input 110 VAC, 220 VAC, 380 VAC
Current Input 1 A, 5 A
Analog Output 4-20 mA, 0-5 VDC
The Var Transducers VAR95 are used to convert single or three phase unbalance load reactive power into a proportional load independent DC. output. Based fully electronic Time-Division Multiplication measuring principle, the reactive power of a network with any power factor range are linearly produced by Var Transducers output.
Calibration var of rated output
Connection | V=110V | V=220V | V=380V | ||||||
|
|
|
|||||||
Single Phase |
|
|
|
||||||
3phase,3wire |
|
|
|
||||||
3phase,4wire |
|
|
|
Note. V= Line voltage
Equation to calculated measuring range
Measuring range = Calibration var x PT ratio x CT ratio
Example 3phase,3wire, PT 220V/110V, CT 250/5A, Calibration var = 1000W
Measuring range = 1000 x (220/110) x (250/5) = 100 Kvar.
Warranty:
5 years
WAT95: Watt Transducer
- High accuracy
- Long term stability - Time-Division Multiplication principle |
General Features and Benefits:
High accuracy
Long term stability
Time - Division Multiplication principle
Watt Transducers WAT95 are used to convert single or three phaseunbalance load active power into a proportional load independent DC. Output. Based fully on electronic Time-Division Multiplication measuring principle, the true power of a network with any power factor range are linearly produced by Watt Transducer output.
Calibration watt of rated output |
||||||
Connection |
V=110V |
V=220V |
V=380V |
|||
|
I=1A |
I=5A |
I=1A |
I=5A |
I=1A |
I=5A |
Single Phase |
100W |
500W |
200W |
1000W |
- |
- |
3phase,3wire |
200W |
1000W |
400W |
2000W |
600W |
3000W |
3phase,4wire |
200W |
1000W |
400W |
2000W |
600W |
3000W |
Note. V= Line voltage
Equation to calculated measuring range |
Warranty:
5 years
CT195: Current Transducer (3 phase)
- Current Input 0-1 Aac, 0-5 Aac
- Analog Output 4-20 mA, 0-5 VDC, 0-10 VDC |
General Features and Benefits:
Current Input 0-1 Aac, 0-5 Aac
Analog Output 4-20 mA, 0-5 VDC, 0-10 VDC
Current Transducer CT195 is designed for converting 3 phase sinusoidal alternating current into a load independent DC output signal proportional to the measured RMS. input values.
Warranty:
5 years
CT95: Current Transducer
- Current Input 0-1 Aac, 0-5 Aac
- Analog Output 4-20 mA, 0-5 VDC, 0-10 VDC |
General Features and Benefits:
Current Input 0-1 Aac, 0-5 Aac
Analog Output 4-20 mA, 0-5 VDC, 0-10 VDC
Current Transducer CT95 is designed for converting sinusoidal alternating current into a load independent DC output signal proportional to the measured RMS. input values.
Warranty:
5 years
VT195: Voltage Transducer (3 phase)
- Input 3 Phase, 0-150 VAC,0-300 VAC
- Analog Output 4-20 mA, 0-5 VDC, 0-10 VDC |
General Features and Benefits:
Input 3 Phase, 0-150 VAC,0-300 VAC
Analog Output 4-20 mA, 0-5 VDC, 0-10 VDC
Voltage Transducer VT195 is designed for converting 3 phase sinusoidal alternating voltage into a load independent DC output signal proportional to the measured RMS input values.
Warranty:
5 years
VT95: Voltage Transducer
- Voltage Input 0-150 VAC, 0-300 VAC
- Analog Output 4-20 mA, 0-5 VDC, 0-10 VDC |
General Features and Benefits:
Voltage Input 0-150 VAC, 0-300 VAC
Analog Output 4-20 mA, 0-5 VDC, 0-10 VDC
Voltage Transducer VT95 is designed for converting sinusoidal alternating voltage into a load dependent DC output signal proportional to the measured RMS input values.
Warranty:
5 years