Data Acquisition, MODBUS I/O Module (RS-232, RS-485)

EX24: Analog Expansion Module

- Programmable Input Type

- 16 Analog Input Channels

- DIN Rail Mounting

General Features and Benefits: 

Programmable Input Type

16 Analog Input Channels

DIN Rail Mounting

            Analog Expansion Module EX24 is extension analog input for Analog Input Module AI210 which will provide total of 24 channels of analog inputs and there is all programmable input.

 

 

Warranty: 
5 years
Specifications

Analog Input

Number of channel:

16 Channels

Input type:

Programmable Input (AI210, DL2200 Module)

ADC Resolution:

16 Bits

Isolation:

Relay Isolated

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W160 x H90 x D60 mm.

Warranty

Warranty Period:

5 year

Ordering
Ordering Information:  
Example EX24
Packagelist

Package Checklist

1. EX24

2. Resistor 250 Ω

Downloads
Manual: 
Group Order
Product Order: 
3

DP60: Big Digital Remote Display

- 7-Segment LED Display

- 6 Digits Display

- 100 mm. Height

- Controlled by MODBUS Protocol

  (RS-485)

General Features and Benefits: 

7-Segment LED Display

6 Digits Display

100 mm. Height

Controlled by MODBUS Protocol (RS-485)

            Big Digital Remote Display DP60 Display LED 7 - segment command via RS485 with MODBUS protocol.

            DP60 is Slave and receiving command from Master such as PLC, Touch Screen or even Personal computer with display 6 digits.

 

 

Warranty: 
5 years
Specifications

Serial Interface

Serial Standards:

RS485 (Isolated) 2 Pin Terminal Block

Loading:

RS485 Max 32 Unit

Distance:

RS485 Length 1 Km.

Protocol:

MODBUS ASCII/RTU, Wisco ASCII

Serial Parameter

Baud Rate:

4800, 9600, 14400, 19200, 28800, 38400, 57600, 115200

Data Bits:

7, 8

Stop Bits:

1, 2

Parity:

None, Even, Odd

Monitor

Display:

6 Digits, 100 mm. (7-Segment)

Display Color:

Red (std)

Power Requirements

Power Supply:

110 VAC, 220 VAC ± 20 %

12 VDC, 24 VDC ± 20 % (Optional)

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W590 x H140 x D60 mm.

Wiring:

Screw Terminals

Warranty

Warranty Period:

5 Year

Ordering
Ordering Information: Specify Power Supply
Example /220 VAC
Packagelist

Package Checklist

1. DP60

2. Cable Config

Downloads
Group Order
Big Digital Display: 
5
Product Order: 
11

DP24: Digital Remote Display

- 7-Segment LED Display

- 4 Digits Display

- Controlled by MODBUS Protocol (RS-485)

General Features and Benefits: 

7-Segment LED Display

4 Digits Display

Controlled by MODBUS Protocol (RS-485)

            Digital Remote Display DP24 is LED 7-segment displays using Port RS-485 with MODBUS Protocol

           DP24 is Slave function, command by Master such as PLC, Touch Screen or computer PC. It has 4 digits display

 

 

 

Panel Cutout

Warranty: 
5 years
Specifications

Serial Interface

Serial Standards:

RS485 (Isolated) 2 Pin Terminal Block

Loading:

RS485 Max 32 Unit

Distance:

RS485 Length 1 Km.

Protocol:

MODBUS ASCII/RTU

Serial Parameter

Baud Rate:

4800, 9600, 19200, 57600

Data Bit:

8

Stop Bit:

1

Parity:

None

Monitor

Display:

4 Digits, 10 mm. (7-segment)

Display Color:

Red (std)

Power Requirements

Power Supply:

110 VAC, 220 VAC ± 20 %

12 VDC, 24 VDC ± 20 % (Optional)

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W96 x H48 x D120 mm.

Panel Cutout:

W90 x H40 mm.

Mounting:

Panel Flash Mounting

Wiring:

Screw Terminals

Warranty

Warranty Period:

5 Year

Ordering
Ordering Information: Specify Power Supply
Example DP24/220 VAC
Packagelist

Package Checklist

1. DP24

Downloads
Group Order
Digital Panelmeter: 
10
Product Order: 
10

DP23: Digital Remote Display

- 7-Segment LED Display

- 8 Digits Display

- Controlled by MODBUS Protocol (RS-485)

General Features and Benefits: 

7-Segment LED Display

8 Digits Display

Controlled by MODBUS Protocol (RS-485)

            Digital Remote Display DP23 is LED 7-segment displays using Port RS-485 with MODBUS Protocol

            DP23 is Slave function, command by Master such as PLC, Touch Screen

 

 

 

Panel Cutout

Warranty: 
5 years
Specifications

Serial Interface

Serial Standards:

RS485 (Isolated) 2 Pin Terminal Block

Loading:

RS485 Max 32 Unit

Distance:

RS485 Length 1 Km.

Protocol:

MODBUS ASCII/RTU

Serial Parameter

Baud Rate:

4800, 9600, 19200, 57600

Data Bit:

8

Stop Bit:

1

Parity:

None

Monitor

Display:

8 Digits, 10 mm. (7-segment)

Display Color:

Red (std)

Power Requirements

Power Supply:

110 VAC, 220 VAC ± 20 %

12 VDC, 24 VDC ± 20 % (Optional)

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W96 x H48 x D120 mm.

Panel Cutout:

W90 x H40 mm.

Mounting:

Panel Flash Mounting

Wiring:

Screw Terminals

Warranty

Warranty Period:

5 Year

Ordering
Ordering Information: Specify Power Supply
Example DP23/220 VAC
Packagelist

Package Checklist

1. DP23

2. Manual

Downloads
Group Order
Digital Panelmeter: 
9
Product Order: 
9

DO2000: Digital Output Module

- 16 Digital Output (Relay

  Contact)

– Protocol MODBUS or ASCII

  Command

- RS232, RS485 Isolated (1000 V)

General Features and Benefits: 

16 Digital Output (Relay Contact)

Protocol MODBUS or ASCII Command

RS232, RS485 Isolated (1000 V)

            Digital Output Module DO2000 is the device with 16 relay contract outputs. DO2000 can be communicate through RS-232 or RS-485 connect with computer or PLC in order to control relay output such as ON-OFF electric system, control Motor etc.

Warranty: 
5 years
Specifications

Serial Interface

Serial Standards:

RS232 Connector RJ12 6 Pin

RS485 (Isolated) 4 Pin Terminal Block

Loading:

RS485 Max 32 Unit

Distance:

RS232 Length 15 m.

RS485 Length 1 Km.

Protocol:

MODBUS ASCII/RTU, Wisco ASCII

Support Software:

Citect, Wonderware, LAB View etc.

Serial Parameter

Baud Rate:

4800, 9600, 19200, 57600

Data Bits:

8

Stop Bits:

1

Parity:

None

Relay Output

Number of Channel:

16 Channels

Relay Type:

N.O.

Contact Rating:

5 A @ 250 VAC

5 A @ 30 VDC

Power Requirements

Power Supply:

85 to 230 VAC

12 to 35 VDC Optional

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W160 x H90 x D60 mm

Mounting:

DIN Rail

Warranty

Warranty Period:

5 year

Ordering
Ordering Information: Specify Power Supply
Example DO2000/220 VAC
Packagelist

Package Checklist

1. DO2000

2. RS-232 Cable

Downloads
Group Order
Product Order: 
8

DIO2100: Digital Input/Output Module

- 16 Digital Input (Isolated

  1000 V)

- 8 Digital Output (Relay Contact)

- RS485 Isolated

General Features and Benefits: 

16 Digital Input (Isolated 1000 V)

8 Digital Output (Relay Contact)

RS485 Isolated

            Digital Input/Output Module DIO2100 has 16 Digital Input channels and 8 Relay Contact of Digital Output channels. DIO2100 is set up by RS-232 or RS-485 connector, therefore computer or PLC can be connected. Application Example are machine status display, Alarm status, Control ON-OFF status.

Warranty: 
5 years
Specifications

Serial Interface

Serial Standards:

RS485 (Isolated) 2 Pin Terminal Block

Loading:

RS485 Max 32 Unit

Distance:

RS485 Length 1 Km.

Protocol:

MODBUS ASCII/RTU, Wisco ASCII

Support Software:

Citect, Wonderware, LAB View etc.

Serial Parameter

Baud Rate:

4800, 9600, 19200, 57600

Data Bits:

8

Stop Bits:

1

Parity:

None

Digital Input

Number of Channel:

16 Channels

Sensor Type:

Wet Contact or Dry Contact

Wet Contact (DI to COM):

ON : 12 to 24 VDC

OFF : 0 VDC

Dry Contact (DI to GND):

ON : Short to GND

OFF : Open

Isolation:

Opto Isolated

Relay Output

Number of Channel:

8 Channels

Relay Type:

N.O.

Contact Rating:

5 A @ 250 VAC

5 A @ 30 VDC

Power Requirements

Power Supply:

85 to 230 VAC

12 to 35 VDC (Optional)

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W160 x H90 x D60 mm

Mounting:

DIN Rail

Warranty

Warranty Period:

5 year

Ordering
Ordering Information: Specify Power Supply
Example DIO2100/220 VAC
Packagelist

Package Checklist

1. DIO2100

Downloads
Group Order
Product Order: 
6

DI2000: Digital Input Module


- 32 Digital Input (Opto Isolated)

- RS232, RS485 Isolated

- MODBUS Protocol

- DIN Rail Mounting

General Features and Benefits: 

32 Digital Input (Opto Isolated)

RS232, RS485 Isolated

MODBUS Protocol

DIN Rail Mounting

            Digital Input Module DI2000 is device that received Digital Input for 32 channels. There is RS-232 and RS-485 connector, therefore, computer, PLC, Touch Screen can be connected. Application example are display machine status, alarm status, expand digital input of PLC etc.

 

Warranty: 
5 years
Specifications

Serial Interface

Serial Standards:

RS232 Connector RJ12 6 Pin

RS485 (Isolated) 4 Pin Terminal Block

Loading:

RS485 Max 32 Unit

Distance:

RS232 Length 15 m.

RS485 Length 1 Km.

Protocol:

MODBUS ASCII/RTU, Wisco ASCII

Support Software:

Citect, Wonderware, LAB View etc.

Serial Parameter

Baud Rate:

4800, 9600, 19200, 57600

Data Bits:

8

Stop Bits:

1

Parity:

None

Digital Input

Number of Channel:

32 Channels

Sensor Type:

wet Contact

wet Contact (DI to GND):

ON : 12 to 24 VDC

OFF : 0 to 3 VDC

Isolation:

Opto Isolated

Power Requirements

Power Supply:

110, 220 VAC

12 VDC, 24 VDC (Optional)

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W160 x H90 x D60 mm

Mounting:

DIN Rail

Warranty

Warranty Period:

5 year

Ordering
Ordering Information: Specify Power Supply
Example DI2000/220 VAC
Packagelist

Package Checklist

1. DI2000

2. RS-232 Cable

Downloads
Group Order
Product Order: 
5

DC2100:Digital Counter Module

– 16 Digital Input Channels

– Channel 1-8 can be Programmable (Status, Counter, Frequency)

– Support Protocol MODBUS RTU or ASCII Command

– Support Quadrature Counter, Frequency (Hz) Mode

General Features and Benefits: 

16 Digital Input Channels

Channel 1-8 can be Programmable (Status, Counter, Frequency)

Support Protocol MODBUS RTU or ASCII Command

Support Quadrature Counter, Frequency (Hz) Mode

            Digital Counter Module DC2100 Consist of 16 Digital Inputs which are capable for Source, Sink and Dry Contact. Channel 1 - 8 are able to program input as Status, Counter or Frequency. Computer PC and PLC can connect to device using Port RS485 communication. Counter and Rate can be read using Modbus Protocol (MODBUS ASCII or RTU)



Warranty: 
5 years
Specifications

Serial Interface

Serial Standards:

RS485 (Isolated) 3 Pin Terminal Block

Loading:

RS485 Max 32 Unit

Distance:

RS485 Length 1 Km.

Protocol:

MODBUS ASCII/RTU

Support Software:

Citect, Wonderware, LAB View etc.

Serial Parameter

Baud Rate:

4800, 9600, 19200, 57600

Data Bits:

8

Stop Bits:

1

Parity:

None

Digital Input

Number of Channel:

16 Channels

Sensor Type:

Wet Contact or Dry Contact

Wet Contact (DI to COM):

ON: 12 to 24 VDC

OFF: 0 VDC

Dry Contact (DI to GND):

ON: Short to GND

OFF: Open

Status Mode:

ON, OFF

Counter Mode:

Add, Subtract, Up/Down, Preset (Up/Down),

Run/Hold, Quadrature, Frequency (Hz)

Frequency Mode:

Low: 0.1 Hz

High: 100 Hz

Minimum Pulse Width:

2 msec.

ADC Resolution:

32 Bits

Isolation:

Opto isolated

Power Requirements

Power Supply:

12 to 35 VDC

Power Consumption

Standby:

30 mA @ 12 VDC

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W88 x H133 x D31 mm.

Mounting:

DIN Rail

Warranty

Warranty Period:

5 year

Ordering
Ordering Information:  
Example DC2100
Packagelist

Package Checklist

1. DC2100

Downloads
Group Order
Product Order: 
7.1

AI210: Analog Input Module

- Programmable Input Type

- 8 Analog Input Channels

- 4 Digital Input Channels

- 4 Digital Output Channels

- RS-232, RS-485 Isolated

General Features and Benefits: 

Programmable Input Type

8 Analog Input Channels

4 Digital Input Channels

4 Digital Output Channels

RS-232, RS-485 Isolated

            Analog Input Module AI210 has 8 Analog Input, 4 Digital Input and 4 Digital out. In addition, Analog Input is programmable input, user can set to use with various kind of sensor such as Thermocouple, RTD and Voltage etc. AI210 provides RS-232 connector and RS-485 connector which suitable for developing PC software, PLC, and touch screen display.

            AI210 provides RS-232 connector and RS-485 connector which suitable for developing PC software, PLC, and touch screen display. AI210 has MODBUS ASCII protocol, MODBUS RTU protocol, moreover DDE Server to connect with windows program. Data file can be converting to MS word or MS excel using utility program.

 

Connection via RS485

 

Connection via Ethernet


Product Review

Warranty: 
5 years
Specifications

Serial Interface

Serial Standards:

RS232 Connector RJ12 6 Pin

RS485 (Isolated) 2 Pin Terminal Block

Loading:

RS485 Max 32 Unit

Distance:

RS232 Length 15 m.

RS485 Length 1 Km.

Protocol:

MODBUS (ASCII, RTU), Wisco ASCII

Support Software:

Citect, Wonderware, Lab View, Fix, Genesis, etc.

Serial Parameter

Baud Rate:

4800, 9600, 19200, 57600

Data Bits:

8

Stop Bits:

1

Parity:

None

Analog Input

Number of Channel:

8 Channels up to 24 Channels (EX24 Module)

Input Type:

Programmable Input

Input Range:

Thermocouple (R, S, K, E, J, T, B)

RTD (Cu10, PT100, PT1000)

Resistance (0 to 600 Ω, 0 to 1.2 KΩ, 0 to 4 KΩ)

Voltage mVDC (0 to 80, 0 to 150 mVDC)

Voltage (0 to 1, 0 to 5, 0 to 15, 0 to 30 VDC)

Current (4 to 20, 0 to 20, 0 to 40 mA)

ADC Resolution:

16 Bits

Isolation:

Relay Isolated

Digital Input

Number of Channel:

4 Channels

Sensor Type:

wet Contact (Opto Isolated)

wet Contact (DI to GND):

ON: 12 to 24 VDC

OFF: 0 to 3 VDC

Digital Output

Number of Channel:

4 Channels

Output Type:

NPN Open Collector

Recording

Recording Interface:

1 Sec - 18 Hours (Programmable)

Record Mode:

Stop When Full or Roll Over

Data Format:

Can be Exported to MS Excel

Power Requirements

Power Supply:

85 to 230 VAC

12, 24 VDC (Optional)

Power Consumption

Standby:

280 mA @ 12 VDC

Start Record:

350 mA @ 12 VDC

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W160 x H90 x D60 mm.

Mounting:

DIN Rail

Warranty

Warranty Period:

5 year

Ordering
Ordering Information: Specify Power Supply
Example AI210/85-230VAC
Packagelist

Package Checklist

1. AI210

2. RS-232 Cable

3. Resistor 250 Ω

Downloads
Group Order
Product Order: 
2

AI210: Analog Input Module

- Programmable Input Type

- 8 Analog Input Channels

- 4 Digital Input Channels

- 4 Digital Output Channels

- RS-232, RS-485 Isolated

 

General Features and Benefits: 

Programmable Input Type

8 Analog Input Channels

4 Digital Input Channels

4 Digital Output Channels

RS-232, RS-485 Isolated

            Analog Input Module AI210 has 8 Analog Input, 4 Digital Input and 4 Digital out. In addition, Analog Input is programmable input, user can set to use with various kind of sensor such as Thermocouple, RTD and Voltage etc. AI210 provides RS-232 connector and RS-485 connector which suitable for developing PC software, PLC, and touch screen display.

            AI210 provides RS-232 connector and RS-485 connector which suitable for developing PC software, PLC, and touch screen display. AI210 has MODBUS ASCII protocol, MODBUS RTU protocol, moreover DDE Server to connect with windows program. Data file can be converting to MS word or MS excel using utility program.

 

Connection via RS485

 

Connection via Ethernet


Product Review

Warranty: 
5 years
Specifications

Serial Interface

Serial Standards:

RS232 Connector RJ12 6 Pin

RS485 (Isolated) 2 Pin Terminal Block

Loading:

RS485 Max 32 Unit

Distance:

RS232 Length 15 m.

RS485 Length 1 Km.

Protocol:

MODBUS (ASCII, RTU), Wisco ASCII

Support Software:

Citect, Wonderware, Lab View, Fix, Genesis, etc.

Serial Parameter

Baud Rate:

4800, 9600, 19200, 57600

Data Bits:

8

Stop Bits:

1

Parity:

None

Analog Input

Number of Channel:

8 Channels up to 24 Channels (EX24 Module)

Input Type:

Programmable Input

Input Range:

Thermocouple (R, S, K, E, J, T, B)

RTD (PT100)

Voltage mVDC (0 to 100 mVDC)

Voltage (0 to 10, 0 to 5 VDC)

Current (0 to 20, 0 to 40 mA)

ADC Resolution:

16 Bits

Isolation:

Relay Isolated

Digital Input

Number of Channel:

4 Channels

Sensor Type:

wet Contact (Opto Isolated)

wet Contact (DI to GND):

ON: 12 to 24 VDC

OFF: 0 to 3 VDC

Digital Output

Number of Channel:

4 Channels

Output Type:

NPN Open Collector

Recording

Recording Interface:

1 Sec - 18 Hours (Programmable)

Record Mode:

Stop When Full or Roll Over

Data Format:

Can be Exported to MS Excel

Power Requirements

Power Supply:

85 to 230 VAC

12, 24 VDC (Optional)

Power Consumption

Standby:

280 mA @ 12 VDC

Start Record:

350 mA @ 12 VDC

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W160 x H90 x D60 mm.

Mounting:

DIN Rail

Warranty

Warranty Period:

5 year

Ordering
Ordering Information: Specify Power Supply
Example AI210/85-230VAC

 

Packagelist

Package Checklist

1. AI210

2. RS-232 Cable

3. Resistor 250 Ω

4. Manual

5. CD Software

Downloads
Group Order
Product Order: 
2
Syndicate content