DL2200:Data Logger

- 8 Channels Analog Input

  (Programmable input)

- 24 Channels Analog Input

  เมื่อเพิ่ม Module EX24

- 4 Digital Input / Output

- Isolation Analog Input with Relay, Digital

  Input with Optoelectronic

- Easily configure at Panel LCD and

  Keyboard

- Use SD card memory for Data Storage

  (4GB)

- Stand Alone Data Logger and Real Time

  Data Acquisition

            Data logger DL2200 is Device for recording Analog signal and Digital signal. Data will be record using Memory Card which is removable and it can be download using computer.

            Analog Input of DL2200 is programmable input which can set as various kind of sensor such as Thermocouple, PT100, PT1000, Voltage and Current

            Data can be display as table also it can be display as Trend Graph. Utility program which come with the device, has option of export file as CSV. Which is compatible with Windows programs such as Excel and Word.

การเชื่อมต่อกับเครื่องคอมพิวเตอร์ผ่านทาง Internet (RC34)

การเชื่อมต่อกับเครื่องคอมพิวเตอร์ผ่านทาง Wireless (RC35)

Specifications

USB Interface

Compliance:

USB 1.1/2.0

Connector:

USB Type B

Speed:

12 Mbps (Full-Speed USB)

Class:

CDC

Operating System:

Windows 98/SE, ME, NT, 2000, XP, 7, Vista

Serial Interface

Serial Standards:

RS232 Connector RJ12 Connector

RS485 (Isolated) 2 Pin Terminal Block

Loading:

RS485 Max 32 Unit

Distance:

RS232 Length 15 m.

RS485 Length 1 Km.

Protocol:

MODBUS ASCII/RTU, Wisco ASCII

Supply Software:

Citect, Wonderware, LAB View etc.

Serial Parameter

Baud Rate:

4800, 9600, 19200, 38400, 57600, 115200

Data Bits:

7,8

Stop Bits:

1,2

Parity:

None, Even, Odd

Analog Input

Number of Channel:

8 Channels up to 24 Channels (EX24 Module)

Input Type:

Programmable Input

Input Range:

Thermocouple (R, S, K, E, J, T, B)

RTD (Cu10, PT100, PT1000)

Resistance (0 to 600 Ω, 0 to 1.2 KΩ, 0 to 4 KΩ)

Voltage mVDC (0 to 80, 0 to 150 mVDC)

Voltage (0 to 1, 0 to 5, 0 to 15, 0 to 30 VDC)

Current (4 to 20, 0 to 20, 0 to 40 mA)

ADC Resolution:

16 Bits

Isolation:

Relay Isolated

Digital Input

Number of Channel:

4 Channels

Sensor Type:

wet Contact

wet Contact (DI to GND):

OFF : 0 to 3 VDC

ON : 12 to 24 VDC

Impedance:

1 KΩ

Counter of Channel:

1 Channel (Channel 4 can use as counter)

Counter Frequency:

100 Hz

Digital Output

Number of Channel:

4 Channels

Output Type:

NPN Open Collector (Remote control)

Over Current Limit:

500 mA @ 50 VDC

Recording

Storage Internal:

4 Gbytes

Storage Expansion:

SD Slot

Recording Interval:

1 Sec to 18 Hours (Programmable)

Record Mode:

Stop when full or Roll Over

Recording by:

Button SW, Schedule, Digital Trig

Data Format:

Can be Exported to MS Excel

Power Requirements

Power Supply:

85 to 230 VAC

12, 24 VDC (Optional)

Power Consumption

Standby:

280 mA @ 12 VDC

Start Record:

350 mA @ 12 VDC

Environmental Limits

Operating Temperature:

0 to 55 °C

Operating Humidity:

5 to 95 %RH

Storage Temperature:

0 to 70 °C

Physical Characteristics

Dimension:

W160 x H90 x D60 mm.

Mounting:

DIN Rail

Warranty

Warranty Period:

5 year

Ordering
Ordering Information: Specify Power Supply
Example DL2200/220VAC
Packagelist

Package Checklist

1. DL2200

2. RS-232 Cable

3. USB Cable

4. Resistor 250 Ω

5. Memory Card

Downloads